Output Object Info
6-3-15 Output Frame Number
Serial Cmd: <K734,output frame number,output coordinates>
Default:
Disabled
Options:
0 = Disabled
Disabled
When Output Frame Number is set to Disabled, the frame number is not output as part of the symbol
data.
Enabled
When Output Frame Number is set to Enabled, the number of the frame in which the symbol was first
decoded is attached to the symbol output information. The output format is "Fnnn", where "nnn" is a 3-
digit decimal value from 0 to 255. The frame number rolls over to 0 once it passes 255.
If this feature is enabled, the frame information will follow the symbol data, and it will precede any symbol
quality data (if symbol quality settings are enabled—see Symbol Quality Separator). The symbol
quality separator is located between the end of the already-formatted data and the "F" that precedes
the frame number.
6-3-16 Output Coordinates
Serial Cmd: <K734,output frame number,output coordinates>
Default:
Disabled
Options:
0 = Disabled
Disabled
When Output Coordinates is set to Disabled, the coordinates are not output as part of the symbol
data.
Enabled
When Output Coordinates is set to Enabled, the four sets of object coordinates for the first
successfully decoded symbol are attached to the symbol data output in the following format:
"(nnn,mmm)", where "nnn" is a 3-digit X-coordinate and "mmm" is a 3-digit Y-coordinate. The validation
separator is located between the end of the already formatted data and the first coordinate point. The
point with the lowest X + Y sum will be output first, followed by the next three points in a clockwise
direction.
Example:
(032,040)(287,056)(287,279)(048,271)
V460-H Industrial Handheld DPM Reader User Manual
1 = Enabled
1 = Enabled
6 Interface Parameters
6
6-31