Fan Failures; Possible Symptoms Of High Cpu Utilization - Cisco Catalyst 9500 Manual

System management configuration guide, cisco ios xe amsterdam 17.2.x
Hide thumbs Also See for Catalyst 9500:
Table of Contents

Advertisement

Troubleshooting the Software Configuration
Note
• Temperature—Temperature of a standalone deicev .
• Uptime data—Time when a standalone device starts, the reason the device restarts, and the length of
• Voltage—System voltages of a standalone device .
You should manually set the system clock or configure it by using Network Time Protocol (NTP).
When the device is running, you can retrieve the OBFL data by using the show logging onboard privileged
EXEC commands. If the device fails, contact your Cisco technical support representative to find out how to
retrieve the data.
When an OBFL-enabled device is restarted, there is a 10-minute delay before logging of new data begins.

Fan Failures

By default, the feature is disabled. When more than one of the fans fails in a field-replaceable unit (FRU) or
in a power supply, the device does not shut down, and this error message appears:
Multiple fan(FRU/PS) failure detected. System may get overheated. Change fan quickly.
The device might overheat and shut down.
To enable the fan failures feature, enter the system env fan-fail-action shut privileged EXEC command. If
more than one fan in the device fails, the device automatically shuts down, and this error message appears:
Faulty (FRU/PS) fans detected, shutting down system!
After the first fan shuts down, if the device detects a second fan failure, the device waits for 20 seconds before
it shuts down.
To restart the device, it must be power cycled.

Possible Symptoms of High CPU Utilization

Excessive CPU utilization might result in these symptoms, but the symptoms might also result from other
causes, some of which are the following:
• Spanning tree topology changes
• EtherChannel links brought down due to loss of communication
• Failure to respond to management requests (ICMP ping, SNMP timeouts, slow Telnet or SSH sessions)
• UDLD flapping
• IP SLAs failures because of SLAs responses beyond an acceptable threshold
This feature is not supported on the C9500-12Q, C9500-16X, C9500-24Q,
C9500-40X models of the Cisco Catalyst 9500 Series Switches.
time the device has been running since it last restarted.
System Management Configuration Guide, Cisco IOS XE Amsterdam 17.2.x (Catalyst 9500 Switches)
Fan Failures
321

Advertisement

Table of Contents
loading

Table of Contents