  • Page 1 Laboratory Refrigerators TSX Series Installation and Operation 327929H01 Rev. A September 2016 Visit us online to register your warranty www.thermofisher.com/labwarranty...
  • Page 2 IMPORTANT Read this instruction manual. Failure to follow the instructions in this manual can result in damage to the unit, injury to operating personnel, and poor equipment performance. CAUTION All internal adjustments and maintenance must be performed by qualified service personnel. Material in this manual is for informational purposes only.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Models ..................1 Safety Precautions..............2 Unpacking.................4 Packing List ................5 General Recommendations .............6 Temperature Monitoring ............6 Intended Use ................6 Operating Standards ...............7 Unit Specifications ...............7 Installation................8 Location ................8 Leveling ................8 Wiring ..................8 Shelves .................9 Drawers ................9 Baskets ................13 Anti-Tip Brackets ...............13 Temperature Sensor Bottles ..........16...
  • Page 4 Table of Contents Cleaning the Condenser Filter ..........31 Cleaning the Condenser .............31 Automatic Defrost ..............32 Gasket Maintenance ............32 Alarm Battery Maintenance ..........32 Troubleshooting ..............33 End of Life Care..............35 Warranty ................36...
  • Page 5: Models

    Refer to Section 6.1 for details on the voltage specifications for the various models. Table 1. Applicable Models Unit Model (*) Thermo Scientific - TSX2305G* A/D/V Thermo Scientific - TSX2305S* A/D/V Thermo Scientific - TSX2305P* A/D/V...
  • Page 6: Safety Precautions

    This symbol indicates possible pinch points which may cause personal injury. This symbol indicates a need to use gloves during the indicated procedures. If performing decontamination procedures, use chemically resistant gloves. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 7 WARNING: This unit is not for storage of flammable materials. WARNING: This unit is charged with hydrocarbon refrigerants. Only qualified service personnel should service this unit. WARNING: Unauthorized repair of your refrigerator will invalidate your warranty. Contact Technical Service at 1-800-438-4851 for additional information. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 8: Unpacking

    Make a written request for inspection to delivering carrier. This must be done within 15 days after delivery. Then file a claim with the carrier. Do not return goods to the manufacturer without written authorization. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 9: Packing List

    If specified on the order, the bag may also include: • QC temperature graph and test log • Calibration information Other items with your unit include: • Power cord • Anti-Tip Bracket Kit • Baskets, Shelves or Drawers • Thermal Bottle Thermo Scientific TSX Laboratory Refrigerators...
  • Page 10: General Recommendations

    This unit is not intended for use in classified hazardous locations, nor to be used for the storage of flammable or corrosive inventory. CAUTION: Storage of unsealed corrosive substances may cause the interior of the unit to corrode. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 11: Operating Standards

    168 (370) † Weight provided is for Laboratory Refrigerator with solid door (TSX2305S*). For a Pharmacy Refrigerator (TSX2305P*), add 45 Kg (100 lbs). For a Laboratory Refrigerator with glass door (TSX2305G*), add 8 Kg (18 lbs). Thermo Scientific TSX Laboratory Refrigerators...
  • Page 12: Installation

    Table 3. Power Cord Specifications Model Power Cord Specifications 3-G 12 AWG, NEMA 5-15P, 15A/125V 3-G 14 AWG, NEMA 6-15P, 15A/250V 3-G 1.5 mm , CEE 7/7, 16A/250V TSX Laboratory Refrigerators Thermo Scientific...
  • Page 13: Shelves

    Note The drawers fit snugly between the slides. Push the back to the drawer from underneath to remove the drawer. 3. Raise the back of the drawer almost to a vertical position and disengage the front mounting clips from the sides. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 14 Drawer slides have a small wire safety clip at the front pilaster which prevent the 7.5.3 Changing Drawer slides from falling when the drawer is removed. To change the position of the Position drawer slides, complete the following steps: 1. Locate the safety clip. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 15 3. Lift up the slide at the front. The slide is free to move from the front pilaster. Figure 4. Front of slide Removal 4. The drawer slide must be removed from the rear pilaster at approximately a 45 degree angle towards the center of the cabinet. Figure 5. Slide Rotation Thermo Scientific TSX Laboratory Refrigerators...
  • Page 16 Figure 7. Clip Replacement Drawer slides do not require lubrication. Additional lubricant could impede movement of the drawers when lubricant is cold. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 17: Baskets

    The use of this bracket does not prevent the tipping of the refrigerator when not properly installed. Figure 8. Materials Supplied Label Description Bracket Bolts Anchors Instructions and Installation Template Thermo Scientific TSX Laboratory Refrigerators...
  • Page 18 Locate 1/2" bolt attached to bottom of cabinet. b. Unscrew 1/2" bolt until there is 1/2" clearance between floor and head of bolt as shown in the Figure 9 below. c. Tighten lock nut against bottom of unit. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 19 Lock the casters. 5. Checking the Installation Check to see if the anti-tip bracket is installed properly by shining light under cabinet and confirming bolt in cabinet is secured by bracket on floor. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 20: Temperature Sensor Bottles

    Refer to Table 5 below: Table 5. Wire Gauges and Distance to Remote Alarm Total Wire Length Distance to Alarm 1/2 Wire Gauge (feet) Wire Length (feet) 1330 2120 1060 3370 1685 TSX Laboratory Refrigerators Thermo Scientific...
  • Page 21: Final Checks

    2. Check the positions of the shelves, drawers and baskets. If you want to adjust the positions, see instructions in Section 7.4, Section 7.5 and Section 7.6. 3. Verify that the unit is connected to a dedicated circuit. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 22: Startup

    • For critical applications, be sure that the alarm systems are working and active before you load any product. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 23 For initial product loading and after removing the drawers or baskets for cleaning, be sure to load the unit from the bottom drawer or basket up to ensure the components are seated properly. (Applicable for drawers and baskets only). Thermo Scientific TSX Laboratory Refrigerators...
  • Page 24: Operation

    For example, suppose that the cabinet temperature setpoint is 5°C and that the warm and cold alarm setpoints are 8°C and 2°C. Then the number of bars illuminated indicates cabinet temperature as follows: TSX Laboratory Refrigerators Thermo Scientific...
  • Page 25 8. Decrease - pushbutton used to decrease setpoint values in programming mode and for various display functions. 9. Scan - pushbutton used to change the main display and for various other functions. 10. Audible alarm - illuminates during warm and cold alarm conditions. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 26: Display Functions

    Press 6 minutes. temperature, alarm icon continues to flash. Return to default display Press Excursion values are reset; temperature Reset after alarm condition, simultaneously, hold display shows cabinet temperature. clears temperature log. for 5 seconds. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 27: Programming Functions

    Be sure to understand your product requirements prior to making any adjustments to the service parameter values. Call Technical Support if you have any questions prior to making any adjustments to service parameter values. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 28 Pressing the Scan button after displaying the defrost Enter Defrost probe temperature while not in an alarm mode will Press Scan ( cycle force the unit into a defrost cycle. To avoid defrost cycle, leave unit screen idle for 30 seconds. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 29: Temperature Settings

    The Mute function (pressing the button) allows you to turn off the audio warning without turning off the visual indicators. The alarm will ring back approximately after 6 minutes if the alarm is still active. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 30 During a low battery condition, the low battery icon will illuminate. The alarms can be reset by pressing and holding the simultaneously. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 31: Chart Recorder (Optional)

    4. Close the recorder door. Note The recorder may not respond until the system reaches temperatures within the recorder’s range. Figure 12. Chart Recorder Label Description Pressure Sensitive Chart Buttons Imprinting Stylus Reference Mark Hub-Nut and Retaining Wire Chart Thermo Scientific TSX Laboratory Refrigerators...
  • Page 32: Changing Chart Paper

    The LED indicator glows continuously when main power is functioning and the battery is charged. When the battery is low, the LED flashes to indicate that the battery needs to be changed. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 33: Calibration And Adjustments

    (#1 and #2 from Figure 13) for 5 seconds. Note The stylus does not begin to move until the button is held for 5 seconds. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 34: Temperature Transmitter

    To connect your remote temperature monitoring system to the temperature transmitter, refer to Figure 14 below. Figure 14. Temperature transmitter Label Description Rear of Unit 16.5V Supply Negative Controller and/or Indicator Customer Provided System Temperature Transmitter Negative Terminal Strip TSX Laboratory Refrigerators Thermo Scientific...
  • Page 35: Maintenance

    In heavy traffic areas, condensers load with dirt more quickly. Failure to keep the condenser clean can result in equipment warm-up or erratic temperatures. CAUTION: Never clean around the condensers with your fingers. Some surfaces are sharp. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 36: Automatic Defrost

    12.6 Alarm Battery Have a certified technician replace the alarm battery every twelve months at most or when the alarm is active. The part number for a replacement battery is Maintenance 322533H01. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 37: Troubleshooting

    12V backup Low battery Replace the battery. It is located on the top right hand side of the cabinet. Call battery needs to icon is lit an authorized service representative. be replaced. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 38 "E05" on display Check for loose probe connector. Replace ambient probe. Failure Upper Bottle Probe "Err" on display Check for loose probe connector. Replace upper bottle probe. Failure Lost “---” on display Call customer service. Communication TSX Laboratory Refrigerators Thermo Scientific...
  • Page 39: End Of Life Care

    2. Remove the cabinet door to help prevent entrapment inside of a unit. 3. Have a certified technician remove the refrigerant and compressor, then drain the compressor and oil from the system. Dispose of components following local regulations. Thermo Scientific TSX Laboratory Refrigerators...
  • Page 40: Warranty

    WARRANT THAT THE PRODUCTS ARE ERROR-FREE OR WILL ACCOMPLISH ANY PARTICULAR RESULT. THERMO FISHER SHALL NOT BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION, DAMAGES TO LOST PROFITS OR LOSS OF PRODUCTS. TSX Laboratory Refrigerators Thermo Scientific...
  • Page 41 Further information on our compliance with these Directives, the recyclers in your country, and information on Thermo Scientific products which may assist the detection of substances subject to the RoHS Directive are available at www.thermo.com/...
  • Page 42 IF YOU NEED ASSISTANCE: Thermo Fisher Scientific products are backed by a global technical support team ready to support your applications. We offer cold storage accessories, including remote alarms, temperature recorders, and validation services. Visit www.thermofisher.com or call: Phone Numbers Sales Service North America...
  • Page 43 Thermo Fisher Scientific Inc. 275 Aiken Road Asheville, NC 28804 United States www.thermofisher.com 327929H01 Rev. A...

Table of Contents