Mixer Configuration And Settings; Sync Clock Screen - Tascam Sonicview 16XP Reference Manual

Multitrack recording console
Table of Contents

Advertisement

4 - Mixer configuration and settings

SYNC CLOCK screen

On this screen, the status of each audio clock is shown and
audio synchronization settings and word clock output jack
output mode settings can be made.
Tap Menu Screen > System Setup > Sync Clock to open this
screen.
1 STATUS display area
This shows the status of each audio clock.
Item
Explanation
This shows the synchronization status of
this unit with the master clock (Locked/
SYNC CLOCK
Unlocked/Regained) and the operation
frequency (96kHz/48kHz/No Signal).
This shows the synchronization status
of this unit with the WORD signal input
through the WORD IN jack (Locked/
WORD IN
Unlocked/Regained) and the operation
frequency (actual measured value/No
Signal).
This shows the synchronization status
of this unit with the connected Dante
system (Locked/Unlocked/Regained)
Dante
and the operation frequency (actual
measured value/No Signal). Tap the
icon to open the Dante Settings page of
the Dante Setup Screen.
These show the names of the expansion
SLOT1
cards in SLOT 1 and 2 and the
synchronization statuses of this unit
with them (Locked/Unlocked/Regained)
SLOT2
and the operation frequency (actual
measured value/No Signal).
NOTE
The operation frequency will not be shown for SLOT 1 or
SLOT 2 if it has an IF-MTR32 (multitrack recording) card
installed.
34
TASCAM Sonicview 16XP/Sonicview 24XP V1.5.0
2 Sync Clock buttons
These set the synchronization clock frequency of the digital
input and output signals.
The selected button will be highlighted light blue.
Options: 48 kHz, 96 kHz (default)
NOTE
i This unit will always operate internally at 96 kHz even when
synchronized to a master clock that is 48 kHz.
i Synchronization is possible even if the built-in Dante
"Sampling rate" and the main unit "Sync Clock" settings are
different.
i Synchronization is not possible if the IF-DA64 (Dante) card
"Sampling rate" is 44.1 or 88.2 kHz.
i If the IF-DA64 (Dante) card "Sampling rate" is 48 or 96 kHz,
synchronization is possible even if the main unit "Sync Clock"
setting is different. (Set the IF-DA64 (Dante card) "Sampling
rate" with Dante Controller.)
i When the Clock Master is Dante, if the "Sampling rate" setting
and Dante sampling rate are different, the following values
will be shown for the operation frequency of the SYNC
CLOCK.
i When the internal Dante "Sampling rate" is "96 kHz" and
Sync Clock is "48 kHz", half the internal Dante measured
value
i When the internal Dante "Sampling rate" is "48 kHz" and
Sync Clock is "96 kHz", twice the internal Dante measured
value
3 Clock Master buttons
These set the master clock used by this unit for audio
synchronization. (default: INT)
o A
mark appears on the master clock being used.
o If the selected master clock is locked, the select button
will be highlighted light blue.
o If Sync Clock is "48 kHz" when the internal Dante
"Sampling rate" is "96 kHz", "1/2" will be shown at the top
right of the Dante button.
o If Sync Clock is "96 kHz" when the internal Dante
"Sampling rate" is "48 kHz", "x2" will be shown at the top
right of the Dante button.
o If the "Sampling rate" of an IF-DA64 (Dante) card installed
in SLOT 1 or SLOT 2 is "96kHz" and Sync Clock is "48kHz",
"1/2" will be shown at the top right of the corresponding
SLOT button.
o If the "Sampling rate" of an IF-DA64 (Dante) card installed
in SLOT 1 or SLOT 2 is "48kHz" and Sync Clock is "96kHz",
"×2" will be shown at the top right of the corresponding
SLOT button.
o If the selected external clock is unlocked, the unit will
operate using the internal clock. In this case the
be shown on the INT button as the clock in use, while
is shown on the selected button for the unlocked source.
The selected button for the unlocked source will be
highlighted red.
will