Information Menu; Resetting The Anomaly History - Immergas EOLO STAR 24 4E Instructions And Warnings

Hide thumbs Also See for EOLO STAR 24 4E:
Table of Contents

Advertisement

2.6

INFORMATION MENU.

Pressing the buttons (3) and (4) simultaneously for 3 seconds,
the "Information menu" is activated, which displays some boiler
functioning parameters.
Press buttons (3) and (4) to scroll through the various parameters.
To exit the menu, press buttons (3) and (4) simultaneously again
for 3 seconds or wait for 5 minutes.
Id Parameter
d1
Displays the flame signal
d2
Displays the primary exchanger output instant flow temperature (flow probe)
d3
Displays the instant output temperature from the DHW exchanger (DHW probe)
d4
Not used
d5
Displays the operating instantaneous power (value in %).
d6
Displays the actual temperature for the central heating set (if remote control is present)
d7
Displays the temperature set for the DHW set (if remote control is present)
E1 - E7
Display the anomaly history, of which E1 is the most recent
2.7

RESETTING THE ANOMALY HISTORY.

Press the "
" button on the information menu for > 2 seconds
and < 5 seconds.
The display will show "E-": at this point release the "
34
Description
" key.

Hide quick links: