BOILER SHUTDOWN.

Press the button (2 Fig. 30) (
the display ( ).
ATTENTION:
In these conditions the boiler is to be
considered still live.
Disconnect the omnipolar switch outside the boiler and close the
gas cock upstream of the appliance. Never leave the boiler switched
on if left unused for prolonged periods.
In the case of prolonged inactivity (second case), we also recom-
mend that:
- the electric power supply is disconnected;
- empty the boiler domestic hot water circuit via the drain valves
(Fig. 29) and the internal domestic hot water distribution net-
work.
2.9
RESTORE CENTRAL HEATING SYSTEM
PRESSURE.
Periodically check the system water pressure. The boiler pressure
gauge should read a value of between 1 and 1.2 bar.
If the pressure is below 1 bar (with the circuit cool) restore normal pres-
sure via the filling cock located in the lower part of the boiler (Fig. 31).
N.B.: close the cock after the operation.
If pressure values reach around 3 bar the safety valve may be
activated.
In this case, remove water from an air vent valve of a radiator until
reaching pressure of 1 bar, or ask for assistance from professionally
qualified personnel.
In the event of frequent pressure drops, contact qualified staff for
assistance to eliminate the possible system leakage.

2.10 DRAINING THE SYSTEM.

1. Ensure that the filling cock is closed.
2. Open the draining cock (Parag. 1.24).
3. Open all vent valves.
4. At the end, close the emptying cock.
5. Close all previously opened vent valves.
Bottom view.
) until the symbol appears on
ATTENTION:
if glycol was input in the system's circuit,
make sure it is discharged into the waste
water system, pursuant to regulation EN 1717
2.11 DRAINING THE DOMESTIC HOT WATER
CIRCUIT.
To do this, always close the domestic cold water inlet upstream
of the appliance.
Open any domestic hot water tap to discharge the pressure from
the circuit.

2.12 CLEANING THE CASE.

Use damp cloths and neutral detergent to clean the boiler casing.
Never use abrasive or powder detergents.

2.13 DECOMMISSIONING.

In the event of permanent shutdown of the boiler, contact profes-
sional staff for the procedures and ensure that the electrical, water
and gas supply lines are shut off and disconnected.
Key:
1 - Filling valve
2 - Draining valve
31