1.11 CONCENTRIC HORIZONTAL KIT INSTALLATION.

• Type C configuration, sealed chamber and fan assisted.
The position of the terminal (in terms of distances from openings,
overlooking buildings, floor, etc.) must be in compliance with
the regulations in force.
This terminal is connected directly to the outside of the building
for air intake and flue exhaust.
The horizontal kit can be installed with the rear, right side, left
side or front outlet.
For installation with frontal outlet, one must use the fixing plate
and a concentric bend coupling in order to ensure sufficient space
to carry out the tests required by law upon commissioning.
• External grid.
Both the Ø 60/100 and Ø 80/125 intake/exhaust terminal, if
properly installed, is pleasant to look at on the outside of the
building. Make sure that the external silicone wall sealing plate
is properly inserted in the wall.
ATTENTION:
for correct functioning of the system
the terminal with grid must be installed
correctly ensuring that, the "high" indication
present on the terminal is respected on instal-
lation.
2
1
The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Int./exhaust concentric terminal Ø 60/100 (3)
N° 1 - Internal wall sealing plate (4)
N° 1 - External wall sealing plate (5)
2
3
1
The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Adapter Ø 80/125 (3)
N° 1 - Concentric intake-exhaust
terminal Ø 80/125 (4)
18
3
4
5
4
5
6
N° 1 - Internal wall sealing
plate (5)
N° 1 - External wall sealing
plate (6)
• Mounting the horizontal intake-exhaust kit Ø 60/100 (Fig.
11).
Install the bend with flange (2) on the central hole of the boiler,
positioning gasket (1) with the circular projections downwards
in contact with the boiler flange, and tighten using the screws
present in the kit.
Fit the Ø 60/100 (3) concentric terminal pipe with the male side
(smooth) to the female side of the bend (2) up to the end stop,
making sure that the internal and external wall sealing plates have
been fitted; this will ensure sealing and joining of the elements
making up the kit.
• Extensions for Ø 60/100 horizontal kit. Kit assembly (Fig. 12).
The kit with this configuration can be extended up to a max.
horizontal length of 3 m including the terminal with grid and
excluding the concentric bend leaving the boiler. This configu-
ration corresponds to a resistance factor of 100.
In this case the special extensions must be requested.
N.B.: when the boiler is installed in areas where very cold tem-
peratures may be reached, a special anti-icing kit is available that
may be installed as an alternative to the standard kit.