Advertisement

Maximum hea-
P12
ting setting
Temperature
P13
gradient
Pump functio-
P14
ning
Gas valve
P15
calibration
P16
Valve check
P17
Solar delay
P18
Display lighting
Flow off tempe-
P19
rature increase
(Central heating)
44
Defines the maximum flow temperature
Change the insufficient circulation intervention value (E27)
The pump can function in two ways:
oF intermittent: in "winter" mode, the circulator is managed by the room
thermostat or by the remote control.
on continuous: in "winter" mode the circulator is always powered and is
therefore always in operation.
Not used on this model.
Not used on this model.
The boiler is set to switch-on immediately after a request for DHW. In the
case of coupling with a solar storage tank positioned upstream from the
boiler, it is possible to compensate the distance between the storage tank
and the boiler in order to allow the water to reach the boiler. Set the time
necessary to verify that the water is hot enough not to start the boiler.
Establishes the display lighting mode:
00 = (Off) the display lights on if buttons are pressed (time out = 15 secon-
ds).
01 = (Auto) equal to 00, it also lights on to indicate the flame presence.
02 = (On) always on.
Increases the flow off temperature at ignition only in the first 30 seconds.
35 - 80 °C
80°C
00 - 15
(0 = Function
11
deactivated)
oF - on
oF
- - -
- - -
- - -
- - -
00 - 60
(00 = Function
00
deactivated)
01 - 60 seconds
00 - 02
01
on - oF
on