Before installing the appliance, ensure it has been
delivered in perfect condition; if in doubt, contact
the supplier immediately. Packing materials (staples,
nails, plastic bags, polystyrene foam, etc.) constitute a
hazard and must be kept out of the reach of children.
If the appliance is installed inside or between cabinets, ensure
sufficient space for normal servicing; therefore it is advisable to
leave clearance of at least 3 cm between the boiler casing and
the vertical sides of the cabinet.
Leave adequate space above the boiler for possible water and
flue removal connections (Fig. 3).
It is just as important that the intake grids and exhaust
terminals are not obstructed.
It is recommended to check that no flue gas recirculation
is found in the air sample points (0.5% maximum per-
mitted CO2).
Keep all flammable objects away from the appliance (paper,
rags, plastic, polystyrene, etc.).
The minimum distance for exhaust pipes from flammable
materials must be at least 25 cm.
Do not place household appliances underneath the boiler as
they could be damaged if the safety valve intervenes (if not
conveyed away by a draining funnel), or if there are leaks from
the hydraulic connections; otherwise, the manufacturer cannot
be held responsible for any damage caused to the household
appliances.
For the aforementioned reasons, we recommend not placing
furnishings, furniture, etc. under the boiler.
In the event of malfunctions, faults or incorrect operation, turn
the appliance off immediately and contact an authorised com-
pany (e.g. the Authorised Technical Assistance centre, which
has specifically trained staff and original spare parts). Do not
attempt to modify or repair the appliance alone.
Any modification to the appliance that is not explicitly indicated
in this section of the booklet is forbidden.
Installation Standards:
- this boiler must not be installed outdoors,
even in a partially protected area. A partially
protected area is one in which the boiler is
not exposed to the direct action of the weath-
er (rain, snow, hail, etc.).
- Installation of gas appliances, flue exhaust
pipes and combustion air intake pipes is for-
bidden in places with a fire risk (for example:
garages, closed parking stalls), and in poten-
tially dangerous places.
- Installation on the vertical projection
of cooking hobs is forbidden.
- Installation is also prohibited in plac-
es/environments that constitute common
parts of office condominiums such as stairs,
cellars, entrance halls, attics, lofts, escape
routes, etc. if they are not located inside
technical compartments under the respon-
sibility of each individual building and only
accessible to the user (for the features of the
technical compartments, see the technical
standards in force).
- These boilers are not suitable for installation
on walls made of combustible material.
N.B.: installing the wall recessed frame kit must guar-
antee the boiler stable, efficient support. The recessed
frame kit ensures appropriate support only if installed
correctly (according to the rules of good practice),
following the instructions on its instructions leaflet.
The recessed frame for the boiler is not a supporting
structure and must not replace the wall removed. It is necessary
to position the boiler inside the wall. For safety reasons against
any leaks it is necessary to plaster the boiler housing in the brick
wall.
7