instead and therefore they are provided in the same cell separated by the symbol "/").
INTEGRATIONS INTERVENTION
ORDER
(with set-point not reached and
machine blocked by alarm)
1) Plant integration heater
1
1) Boiler
2
1) Plant integration heater
3
2) After 12 mnutes, boiler
1) Boiler
2) After r12 minutes, plant integra-
4
tion heater
1) DHW integration heater
5
1) Boiler
6
1) DHW integration heater
7
2) After r16 minutes, boiler
1) Boiler
2) After r16 minutes, DHW integra-
8
tion heater
1) Plant/DHW integration heater
9
10 1) Boiler
11 1) Plant/DHW integration heater
2) After r12 minutes, boiler
1) Boiler
2) After r12 minutes, plant/DHW in-
12
tegration heater
INTERVENTION ORDER
(with setpoint not reached)
1) Heat pump
2) After r12 minutes, plant integration
1
heater
1) Heat pump
2
2) After r12 minutes, boiler
1) Heat pump
2) After r12 minutes, plant integration
3
heater
3) After further r12 minutes, boiler
1) Heat pump
2) After r12 minutes, boiler
4
3) After further r12 minutes, plant inte-
gration heater
1) Heat pump
2) After r16 minutes, plant integration
5
heater
1) Heat pump
6
2) After r16 minutes, boiler
1) Heat pump
2) After r16 minutes, plant integration
7
heater
3) After further r16 minutes, boiler
1) Heat pump
2) After r16 minutes, boiler
8
3) After further r16 minutes, DHW inte-
gration heater
1) Heat pump
2) After r12 minutes, plant/DHW inte-
9
gration heater
22
TABLE 1. NORMAL OPERATION IN HEAT PUMP MODE
STATUS
OPERATION
HEAT/
HEAT+SAN HEAT
HEAT/
HEAT+SAN HEAT
HEAT /
HEAT+SAN HEAT
HEAT /
HEAT+SAN HEAT
HEAT+SAN DHW
HEAT+SAN
/
DHW
COOL+SAN
HEAT+SAN DHW
HEAT+SAN DHW
HEAT /
HEAT+SAN HEAT/DHW
HEAT /
HEAT+SAN HEAT/DHW
HEAT /
HEAT+SAN HEAT/DHW
HEAT /
HEAT+SAN HEAT/DHW
TABLE 2. JOINT OPERATION, BRACKET 1
STATUS
OPERATION
HEAT /
HEAT+SAN HEAT
HEAT /
HEAT+SAN HEAT
HEAT /
HEAT+SAN HEAT
HEAT /
HEAT+SAN HEAT
HEAT+SAN DHW
HEAT+SAN/ DHW
HEAT+SAN DHW
HEAT+SAN DHW
HEAT /
HEAT+SAN HEAT/DHW
Picco R32
Heat pumps inverter air/water with axial fans
r10
r15
r12
1
0/1/2
/
0/1/2
0/1/2
/
Set the min-
1
0/1/2
utes
Set the min-
1
0/1/2
utes
0/1
1
/
0/1
0/1/2
/
0/1
1
/
0/1
1
/
1
1
/
0/1
0/1/2
/
Set the min-
1
1
utes
Set the min-
1
1
utes
r10
r15
r12
Set the min-
1
0/1/2
utes
Set the min-
0/1
0/1/2
utes
Set the min-
1
0/1/2
utes
Set the min-
1
0/1/2
utes
0/1
1
/
0/1
0/1/2
/
0/1
1
/
0/1
1
/
Set the min-
1
1
utes
r16
r23
r24
/
0/2/5
1/3
/
1/3/4/6 0/2
/
1/3
1/3
/
4/6
1/3
/
0/1/4
2/3
/
2/3/5/6 0/1
Set the min-
2/3
2/3
utes
Set the min-
5/6
2/3
utes
/
0
3
/
3/6
0
Set the min-
3
3
utes
Set the min-
6
3
utes
r16
r23
r24
/
0/2/5
1/3
/
1/3/4/6 0/2
/
1/3
1/3
/
4/6
1/3
Set
the
0/1/4
2/3
minutes
Set
the
2/3/5/6 2/3
minutes
Set
the
2/3
2/3
minutes
Set
the
5/6
2/3
minutes
Set
the
0
3
minutesi