5 Self-Diagnosis Mode
The pump endurance running sequence is as follows.
1. Pump endurance running starts.
2. Pump phase detection is performed.
3. Rotates with the specified suction speed. This rotation is counted as one cycle.
Step 2 above is repeated the number of times specified as follows.
Super High 4000
High 3000
Normal 2000
Low 1000
4. Pump release is performed.
5. Pump endurance running ends.
5.9.6
Print Head Endurance (Nozzle Print) Menu
This menu performs endurance running for the plot head.
In this menu, continuous printing operation can be performed according to the value set. The available
settings are shown below.
Table 5-21 Set Items in Sequential Plotting Endurance Menu
Set item
Media cut
Number of endurance
running cycles
TIP
• If the number of endurance running cycles is set to -1, the carriage continuously repeats endurance
running until cancel input is given from the operation panel.
• The maximum counter value for endurance running cycles is 99999999 (up to 8-digit number). If
the number of cycles exceeds the maximum value, the counter is reset to 0.
Rev.-01
Contents
Set whether or not to cut
the media per plot.
Set the number of
endurance running cycles
[Enter] key
[Enter] key
[Enter] or [Cancel] key
5-68
RJ-900C/RJ-901C/RJ-901M Maintenance Manual
Set value
On / Off
-1 to 10000
Media cut
Endurance Count
Performing endurance running
Remark
Unit: mm