Safety Instructions - Victron energy SmartSolar MPPT RS 450 100 Manual

Table of Contents

Advertisement

1. Safety Instructions

ELECTRIC SHOCK HAZARD
Please read this manual carefully before the product is installed and put into use.
This product is designed and tested in accordance with international standards. The equipment should be used for the designated
application only.
Refer to the specifications provided by the manufacturer of the battery to ensure that the battery is suitable for use with this
product. The battery manufacturer's safety instructions should always be observed.
Protect the solar modules from incident light during installation, e.g. cover them.
Never touch uninsulated cable ends.
Use only insulated tools.
Connections must always be made in the sequence described in the installation section of this manual.
The installer of the product must provide a means for cable strain relief to prevent the transmission of stress to the connections.
In addition to this manual, the system operation or service manual must include a battery maintenance manual applicable to the
type of batteries used. The battery must be placed in a well-ventilated area.
SELECTION OF WIRE CONDUCTORS
Use flexible multistranded copper cable for the battery and PV connections.
The maximum diameter of the individual strands is 0,4mm/0,125mm² (0.016 inch/AWG26).
A 25mm² cable, for example, should have at least 196 strands (class 5 or higher stranding according to VDE 0295, IEC 60228
and BS6360).
An AWG2 gauge cable should have at least 259/26 stranding (259 strands of AWG26)
Maximum operating temperature: ≥ 90°C
Example of suitable cable: class 5 "Tri-rated" cable (it has three approvals: American (UL), Canadian (CSA) and British (BS)).
In case of thicker strands the contact area will be too small and the resulting high contact resistance will cause severe
overheating, eventually resulting in fire.
RISK OF INJURY OR DEATH
The internals can carry a 400-500V DC voltage even when the product is off!
Input and/or output terminals may still be dangerously energized, even when the equipment is switched off. Always disconnect all
power connections (e.g. the battery, DC solar isolator, etc) and wait at least 5 minutes before carrying out work on the product.
The product has no internal user-serviceable components. Do not remove the front plate or operate the product if any panels
have been removed. All servicing must be undertaken by qualified personnel.
Please read the installation instructions in the installation manual before installing the equipment.
This is a Safety Class I product (supplied with a protective grounding terminal). The chassis must be grounded. Whenever it is
likely that the grounding protection has been damaged, the product must be turned off and secured against unintended operation;
please contact qualified service staff.
Non-isolated inverters shall be provided with installation instructions that require PV modules that have an IEC 61730 Class A
rating.
Page 1
www.butlertechnik.com
Isolated SmartSolar MPPT RS
www.butlertechnik.com
Safety Instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartsolar mppt rs 450 200Smartsolar mppt rs 450

Table of Contents