7.3. Appendix D : Dimensions
1
2
A
310
B
442
C
103.5
D
127
E
F
1
2
7.4. Error Codes
7.4.1. Error 2 - Battery voltage too high
This error will auto-reset after the battery voltage has dropped. This error can be due to other charging equipment connected to
the battery or a fault in the charge controller.
7.4.2. Error 3, Err 4 - Remote temperature sensor failure
Check if the T-sense connector is properly connected to a remote temperature sensor. Most likely cause: the remote T-sense
connector is connected to the BAT+ or BAT- terminal. This error will auto-reset after proper connection.
7.4.3. Error 5 - Remote temperature sensor failure (connection lost)
Check if the T-sense connector is properly connected to a remote temperature sensor. This error will not auto-reset.
7.4.4. Error 6, Error 7 - Remote battery voltage sense failure
Check if the V-sense connector is properly connected to the battery terminals. Most likely cause: the remote V-sense connector is
connected in reverse polarity to the BAT+ or BAT- terminals.
7.4.5. Error 8 - Remote battery voltage sense failure (connection lost)
Check if the V-sense connector is properly connected to the battery terminals.
7.4.6. Error 11 - Battery high ripple voltage
High DC ripple is usually caused by loose DC cable connections and/or too thin DC wiring. After the inverter has switched off due
to high DC ripple voltage, it waits 30 seconds and then restarts.
After three restarts followed by a shutdown due to high DC ripple within 30 seconds of restarting, the inverter will shutdown and
stops retrying. To restart the inverter, switch it Off and then On.
Continuous high DC ripple reduces the inverter life expectancy
Page 42
www.butlertechnik.com
Isolated SmartSolar MPPT RS
3
4
5
127
7.5
4x
6
350
26
4
119
3
4
5
www.butlertechnik.com
6
7
Dimension Drawing - SS MPPT 450/100
SCC145110410
SmartSolar MPPT 450/100-Tr VE.Can
32.5
43
55
87.5
175
265
Dimensions in mm
6
7
8
A
6.2(3x)
B
98
87.5
C
D
E
F
8
Appendix