15. Specifications
15.1 General Data
AC adapter
Sartorius AC adapter module
Primary
Secondary
Other data
Balance
Power supply
Input supply voltage
Power consumption
Ambient Conditions
The specifications apply under the following ambient conditions:
Environment
Ambient temperature*
Operational capability
Storage and shipping
Height
Relative humidity**
Safety of Electrical Equipment
Electromagnetic Compatibility
Interference resistance:
Transient emissions:
Standard Equipment
1
Selectable weight units
Available application programs
Verified balances in accordance with EU requirements comply with the requirements of Council Directive 2009/23/EC with
EN 45501:1992 and OIML R76:2006.
* For verified balances in accordance with EU requirements, refer to the information on the balance.
** For verified balances in accordance with EU requirements, the legal regulations apply.
1) Depending on the country-specific model version, not all weight units listed may be available.
6971790 with replaceable, country-specific power plug adapters
100 - 240 V~, -10% / +10%, 50 - 60 Hz, 0.2 A
15 V DC, ± 5%, 530 mA (max.) / 8 W (max.): 0 to +40°C and 15 V DC, ± 5%,
330 mA (max.) / 5 W (max.): 0 to +50°C
Protection class II in accordance with EN/IEC 60950-1 / up to 3000 m above sea level /
IP40 in accordance with EN 60529/IEC 60529
Only via Sartorius AC adapter module 6971790
12.0 - 15.0 V DC
2 W (typically)
For indoor use only
+10°C to +30°C
Guaranteed between +5 °C and +45°C
-10°C to +60°C
Up to 3000 m above sea level
15% to 80% for temperatures up to 31°C non-condensing,
decreasing linearly up to 50 % relative humidity at 40°C and 20 % at 50°C
In accordance with EN 61010-1/IEC 61010-1 Safety requirements for electrical equipment for
measurement, control and laboratory use – Part 1: General requirements
In accordance with EN 61326-1/IEC 61326-1
Electrical equipment for measurement, control and laboratory use – EMC requirements –
Part 1: General requirements
Suitable for use in industrial areas
Class B (suitable for use in residential areas and areas that are connected to a low voltage
network that (also) supplies residential buildings). The device can therefore be used in both
areas.
Gram, kilogram, carat, pound, ounce, troy ounce, Hong Kong tael, Singapore tael, Taiwanese
tael, grain, pennyweight, milligram, parts per pound, Chinese tael, momme, Austrian carat, tola,
baht, mesghal and Newton
®
Secura
models: Counting, percentage, density determination, peak hold, unstable condition,
checkweighing, mixing, components (totalizing), statistics, conversion, SQmin, and identifiers
®
Quintix
models: Counting, percentage, density determination, peak hold, unstable condition,
checkweighing, mixing, components (totalizing), statistics, conversion
®
Practum
models: Counting, percentage, density determination, peak hold, unstable condition,
checkweighing
Specifications
®
®
User Manual Secura
, Quintix
, Practum
®
103