Wacker Neuson BS-2 Operator's Manual page 39

Rammer
Table of Contents

Advertisement

9.3.7
Changing oil in the ramming system
[en] | 07/2022 | 5100056271 | BS-2 | Operator's Manual
Environment
Soil contamination due to oil leaking or overflowing.
► Line work surface with impermeable foil.
► Use collecting container for used oil.
► Dispose of used oil in an environmentally friendly manner in accord-
ance with statutory regulations.
1.
Remove dirt.
2.
Provide a suitable container for draining the used oil.
3.
Unscrew the sight glass.
4.
Clean the thread on the sight glass.
5.
Tilt the machine backwards until it is resting on the guide bracket.
6.
Allow the used oil to drain completely.
7.
Tilt the machine forward and secure it in this position.
8.
Fill oil into the housing through the opening in the sight glass,
Technical data on page
9.
Tighten the sight glass.
10. Place the machine in upright position to check the oil level.
11. If necessary, top up oil until the sight glass ½ to ¾ is filled.
12. Tighten the sight glass again. Tightening torque 9 Nm.
13. Wipe the area of the sight glass with a clean cloth.