Fuel System - Prime; Every 5000 Service Hours Fuel Injector - Inspect/Adjust - Perkins 4012-46A Operation And Maintenance Manual

Industrial engine
Table of Contents

Advertisement

60
Maintenance Section
Fuel Injector - Inspect/Adjust
Illustration 59
Typical example
2. Remove the guards (not shown) in order to gain
access to the fan drive pulley (1).
Illustration 60
3. Tighten the grub screws (2) to a torque of 90 N·m
(66 lb ft).
4. Install the guards (not shown).
5. Restore the electrical supply to the engine.
Fuel Injector - Inspect/Adjust
Only qualified service personnel should perform this
maintenance. Refer to the Service Manual or your au-
thorized Perkins distributor for the complete proce-
dure in order to inspect or adjust the fuel injectors.
Operation of Perkins engines with fuel injectors that
have not been inspected or adjusted can reduce en-
gine efficiency, and also reduce engine component
life.
Refer to Systems Operation, Testing and Adjusting,
"Fuel Injector Adjustment" for the correct procedures
to inspect and adjust the fuel injectors.
g01238304

Fuel System - Prime

If air enters the fuel system, the air must be purged
from the fuel system before the engine can be
started. Air can enter the fuel system when the
following events occur:
The fuel day tank is empty or partially drained.
The low pressure fuel lines are disconnected.
A leak exists in the low pressure fuel system.
The fuel filter has been replaced.
Use the following procedures in order to remove air
g01238305
from the fuel system.
Note: Do not bleed the fuel system from the water
separator (if equipped).
1. Ensure that the fuel system is in working order.
Check that the fuel supply from the fuel day tank
is in the "ON" position.
SEBU8191-01
i03783899
NOTICE
i02415266

Advertisement

Table of Contents
loading

Table of Contents