4. MOUNTING THE TEMPLATE CASING

Install the LUNA SAT model inside the casing/template supplied in a separate pack.
Make sure the template casing model is correct (L= 550x600 mm).
Fit the template/casing in a niche in the wall made for this purpose (dimensions indicated in figures 3 and 4) and secure it
with the relative lateral bent pins. Make sure the installation allows easy access for maintenance.
The casing can be installed in three positions depending on the chosen hydraulic layout:
1) left-right supply
2) high-low supply
3) low-high supply
The right-left layout is not permitted.
Always mount the door and frame with the lock at the top.
Remove the door and white frame and put back after installation (make sure the casing accessories also include the key
for opening the door).
The frame can be depth-adjusted by using the 4 butterfly nuts located in the side guides. It is therefore possible to fit the
frame flush against the plaster and remove it when painting the wall.
Assemble the system starting from the position of the water connectors on the lower crossbar of the template (recessed
into the casing by 86 mm). Install the casing in the stairwell outside the apartment to heat.
L = 550 mm
H = 600 mm
D = 120 mm
I
LEFT-RIGHT
Figure 3: casing/template
INSTALLATION AND OPERATING MANUAL
II
LOW-HIGH
36
III
HIGH-LOW
7215037.01 - en