Figure 2: Floor layout
The indicative diagram in figure 2 only illustrates the feed pipes of the individual user modules.
The heating plant inside the zone controlled by the module must be realised by feeding the heating elements according
to normal methods.
- Water temperature range in centralised plant:
- Maximum water pressure in centralised plant:
- Module feed flow rate (nominal):
- Maximum recommended speed of heat transfer fluid:
- Pressure drop in module
Some purely indicative general sizing data is shown below:
TABLE: HEAT DEMAND – HEATED AREA
Area to heat
(m
)
2
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
(*) Volumetric heat load "F": 20 - 30 - 45 W/m
Height of volume to be heated = 3 m
Δt = internal and external temperature difference (internal T = 20 °C, external T = - 5°C)
F1 = 20 W/m
buildings with an excellent level of insulation
3
F2 = 30 W/m
buildings with an good level of insulation
3
F3 = 45 W/m
buildings with an low level of insulation
3
INSTALLATION AND OPERATING MANUAL
HOME B
3.1 GENERAL SIZING DATA
60 - 75 °C
4 bar
900 ÷ 2500 l/h
1 ÷ 1.5 m/s
18 KPa at 1500 l/h (see § 6)
Heat demand (*)
With F1 = 20 W/m
3
(kW)
3,6
4,2
4,8
5,4
6,0
6,6
7,2
7,8
8,4
9,0
9,6
10,2
10,8
11,4
12
12,6
13,2
13,8
14,4
15
with Δt = 25 K;
3
34
HOME C
Heat demand (*)
With F2 = 30 W/m
3
(kW)
5,4
6,3
7,2
8,1
9
9,9
10,8
11,7
12,6
13,5
14,4
15,3
16,2
17,1
18
18,9
19,8
20,7
21,6
22,5
Heat demand (*)
With F3 = 45 W/m
3
(kW)
8,1
9,5
10,8
12,2
13,5
14,9
16,2
17,6
18,9
20,3
21,6
23,0
24,3
25,7
27,0
28,4
29,7
31,1
32,4
33,8