Q9 OPERATION (continued)
COMPUTER MAINTENANCE (continued)
Batteries (continued)
When batteries are disconnected or fail, the computer memory will retain the batch
total, accumulative total, factory calibration curve, and field calibration curve
indefinitely.
It is strongly recommended that battery checks and terminal cleaning be a part of
a routine maintenance schedule. Battery terminals should be cleaned annually.
Batteries can be replaced without removing the meter from the piping system.
Replace Batteries
1. Remove the (4) corner screws attaching the computer electronics to the meter
and lift the computer electronics from the meter.
2. Remove the batteries.
3. Check the battery terminals and remove any corrosion.
4. Install the new batteries and make sure the positive posts are positioned
correctly. When the batteries are installed correctly, the computer powers on
automatically and the display will show information.
5. Make sure the seal is fully seated before placing the computer electronics back
on the turbine. Tighten the (4) screws previously removed.
6. Do not clean exterior of computer assembly with Isopropyl Alcohol.
Replacement Kits & Accessories
Replacement Kits are available for turbine assemblies and computer assemblies.
Individual components within these assemblies, such as rotors, signal generators,
and buttons are not available. The factory will determine the exact turbine
assembly or computer assembly you need based on your model and serial
number.
Other replacement kits and accessories can be ordered using the part numbers
below.
Part No.
901002-52
116000-1

PARTS

Description
Seal
Large (5 gallon) Calibration Container
Note: Calibration containers are for use with water-based
fluids. Do not use with fuel products.
24