TEL: 316-686-7361 FAX: 316-686-6746 “ A G r e a t P l a i n s Ve n t u r e s S u b s i d i a r y ” www.gpi.net 1-800-835-0113 07/08 Rev. B 920698-06...
To the owner… TABLE OF CONTENTS Congratulations on receiving your GPI General Information ......1 Mechanical Fuel Meter. We at GPI are pleased to provide you with a fuel meter Introduction ......... 1 designed to give you maximum reliability Before Installation ........ 1 and efficiency.
Please take a moment to review them you in operating and maintaining your now for your future safety. GPI mechanical fuel meter. This manual is designed and written with you in mind. Your meter is designed for use only Please take a few moments to read...
Your system must be mounted to a vented Figure 2 tank. (Figure 1) If the tank is unvented, your GPI distributor can supply a pres- sure cap. Figure 1 Replace the counter cover and screws.
Keep the system exterior clean to help identify leaks. WARNING The FM-100 Series has an internal fuel filter. The FM-200 Series is equipped Observe precautions against fire or with an internal strainer. Both should be explosion when dispensing fuel.
Wipe clean the filter can seal, groove CALIBRATION and housing. Coat the seal with oil or light grease and install in the filter The meter is accurately calibrated at the can groove. factory for use with diesel fuel. Due to differences in viscosity and flowrates, Place the filter can over the installed the meter may require recalibration to...
b. If the meter registered less than Figure 9 the quantity in the container, turn the calibration screw clockwise. If the meter display read more than the amount in the container, turn the screw counterclock- wise. Empty the calibration container and repeat steps 2 to 4 until the meter registers the quantity in the container.
4. Broken nutator disc pin Disassemble meter and install new or defective nutator nutator assembly. assembly 5. Missing or jammed Contact GPI Customer Service. counter bevel gear B. METER COUNTER 1. Clogged fuel filter or Replace filter or clean strainer. DOESN’T OPER- strainer...
It may be possible to diagnose the trouble and identify needed parts in For warranty consideration, parts, or other a telephone call or letter. GPI can also service information, contact your local inform you of any special handling require- distributor.
Page 12
B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer’s operating instructions. To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 800-835-0113. Or by mail at: Great Plains Industries, Inc.