Download Print this page
GPI 01A Series Operation Manual

GPI 01A Series Operation Manual

Electronic digital fuel meter

Advertisement

Quick Links

Operations Guide for
01A Series
Electronic Digital Fuel Meter
TABLE OF CONTENTS
English ............................................. 1
Deutsch ............................................ 2
Español ............................................ 4
Français ........................................... 5
Italiano ............................................. 6
E N G L I S H
GENERAL INFORMATION
Congratulations on receiving your GPI
fuel meter. These instructions will help
you operate and maintain your meter.
Content covered in these instructions
include all models in the 01A Series of
Electronic Digital Fuel Meters.
This meter is designed for use only
with gasoline (up to 15% alcohol blends
such as E15), diesel fuel (up to 20%
biodiesel blends such as B20), biodiesel
(B100) and kerosene. Do NOT use it with
water, chemicals or for measuring fluids
into aircraft. This meter is not legal for
trade applications. The 01A Series meter is
very sensitive to electrical "noise" and
may not operate correctly if located near
some electrical equipment. This meter has
a permanent factory calibration for
measuring gasoline, diesel fuel or
kerosene. If installed and used correctly,
you can expect accuracy within ±5%.
01/07
" A G r e a t P l a i n s Ve n t u r e s S u b s i d i a r y "
www.gpi.net
1-800-835-0113
INSTALLATION
Install the meter at the end of the hose
adjacent to the nozzle or horizontally or
vertically in-line. Make sure all threaded
fuel connections are wrapped with three to
four turns of thread tape or pipe thread
sealant approved for use with petroleum
fuels. Make sure the tape does not intrude
into the flow path. Attach the meter to the
hose with the arrow on the outlet port
pointed in the direction of flow. Use
fittings as necessary. Use a wrench at the
housing ends to tighten the meter.
OPERATIONS
This meter will turn on automatically
when it senses fuel flow. It can manually
be turned on by pressing the DISPLAY
button ("DISPLAY"). The meter will show
the total from its last use. The meter turns
off automatically if not used for about one
minute.
Totals
This meter maintains two totals. The
batch total ("TTL1") may be reset to zero
and measures flow during a single use. The
cumulative total ("TTL2") provides
continuous measurement and may not be
manually reset. When the cumulative total
reaches a maximum reading of 9999, it
automatically resets to zero.
Press the DISPLAY button ("DIS-
PLAY") briefly to switch between TTL1
and TTL2. With TTL1 showing, hold the
DISPLAY button down for three seconds
to zero the batch total.
5252 East 36th Street North
Wichita, KS USA 67220-3205
TEL: 316-686-7361
FAX: 316-686-6746
1
Rev. - 920757-01

Advertisement

loading

Summary of Contents for GPI 01A Series

  • Page 1 DISPLAY Content covered in these instructions button (“DISPLAY”). The meter will show include all models in the 01A Series of the total from its last use. The meter turns Electronic Digital Fuel Meters. off automatically if not used for about one This meter is designed for use only minute.
  • Page 2 Auslaßseite in die Flußrichtung. Nach your local distributor or dealer. Bedarf Armaturen einsetzen. Mit einer Rohrzange die Enden des Gehäuses GPI is a registered trademark of Great Plains anschrauben, um den Durchflußmeter zu Industries, Inc. sichern.
  • Page 3 Auskünfte wenden Sie sich bitte an den Laufrad zu entfernen. Wenn Druckluft örtlichen Vertreter oder Großhändler. durch die Turbinengruppe geblasen wird, besteht die Gefahr, das Laufrad zu GPI ist eine eingetragene Schutzmarke der Gesellschaft beschädigen. Great Plains Industries, Inc. Ersetzung der Batterien Zwei AAA alkalische Batterien versorgen den Durchflußmeter.
  • Page 4 PANTALLA («DIS- Le felicitamos por haber elegido el PLAY»). El contador indicará entonces el contador de combustible GPI. Las total de la última utilización. El metro dará siguientes instrucciones le ayudarán a vuelta apagado si no utilizado automática- manejar y mantener el contador.
  • Page 5 Servezvous distribuidor o vendedor local. de garnitures si nécessaire. Serrez la jauge aux extrémités du boîtier à l’aide d’une clé. GPI es una marca registrada de Great Plains Industries, Inc. UTILISATION Cette jauge s’allumera automatique- ment en sentant couler le carburant.
  • Page 6 Il est important que les mouvements du rotor ne soient pas gênés. Appliquez un GPI est une marque déposée de Great Plains Industries, Inc. lubrifiant pénétrant sur le rotor, l’arbre et les roulements, si le rotor se bloque. Servez- vous d’une brosse douce ou d’une petite...
  • Page 7 Questo flussometro è praticamente esente di contattare l’agente o venditore locale. da manutenzione se tenuto pulito e privo di GPI è un marchio registrato della Great Plains sostanze contaminanti. E’ tuttavia importante Industries, Inc. che il girante possa muovere liberamente.
  • Page 8 To make a claim against this warranty, contact the GPI Customer Service Department at 316-686-7361 or 800-835-0113. Or by mail at: Great Plains Industries, Inc.