Commissioning, Start-Up, Operation, Shutdown

Before attempting to start your pump the following must be understood and followed to ensure safe operation.
When running Hypro centrifugal pumps it is essential that operators use hearing protection as the sound levels
can reach levels of 80 decibels.
When handling hypro pumps one should wear steel toed shoes and protective gloves in order to protect the feet in
the event the pump is dropped and protect the hands from any sharp surfaces on the pump or chemicals.
Only authorized operators having the knowledge and skill necessary to safely use a Hypro pump, or any
equipment the pump is connected to, may run the pump.
When spraying manually it is recommended that chemical resistant facemasks and clothing be worn to prevent
any chemicals from coming into contact with the skin or being inhaled.
When spraying manually always spray upwind of yourself as long as the sprayed chemical will not drift into the
vicinity of other people.
When installing, adjusting or removing a Hypro centrifugal pump ensure that there are no objects which can fall on
the installer and make certain that all machinery to which the pump is to be attached is turned off.
Hypro centrifugal pumps should only be used on tractors or tow behind spray platforms which have electrically
conductive tires in order to reduce the risk of electrocution.
Never operate a Hypro centrifugal pump from outside while there is a chance of getting struck by lightning.
Never leave electrical wires or plumbing components where they can be a tripping hazard or become entangled
in a moving component. Ideally electrical cables, hoses, pipes and fittings should be routed overhead. In the event
electrical wiring must be routed over the ground operators are required to use rubber ramps if they cross a gangway.
If users of a Hypro centrifugal pump are using a PTO shaft, flexible coupling or belt drive they are required to use
CE approved PTO shafts and guards
Hypro centrifugal pumps should not be used if the ambient light is below 200lux.
For centrifugal pumps which use gas engines the user should always ensure the exhaust is properly attached to
the engine and is not leaking
Only use approved chemicals in your pump, for a complete list of approved chemicals see the "Fluid
Pumping Applications" section. Failure to follow this warning will void your warranty and could lead to property
damage, serious injury or death.
Before Starting the Pump
Ensure all unnecessary personnel are clear of the area
For initial setup and test of your system, it is recommended to start with clean water instead of chemicals, and confirm
the system and plumbing connections are leak free.
Ensure that there is fluid in the source tank or supply line. Do not run dry.
Check line strainer for debris or clogs. Remove any found.
Check all plumbing connections to make sure they are tight.
Check power source and connections.
Check all valves and regulators are set to the desired setting and are functioning properly.
Ensure all hoses are properly positioned and are not damaged in any way.
Ensure PTO shaft shields are in place and are not loose
Priming the Pump
To help prime the pump, keep the inlet or suction line as short as possible with a minimum of bends, elbows and kinks.
Make sure all connections are tight and do not leak air. Non self-priming pumps must have the inlet line and pump
flooded with liquid before starting the pump. For self-priming models the front chamber should be filled with liquid before