Emergency Operation Procedures Machines With Electric Controls; Operation From Platform Control Station; Electric Control Machines - Snorkel MHP15HD Operator's Manual

Table of Contents

Advertisement

Emergency Operation Procedures
Machines with Electric Controls

Operation from platform control station

electric control machines

Switch set tings listed in the two (2) steps be low
must ex ist at the ground be fore emer gency op er a -
tion pro ce dures will work at the plat form con trol
box:
Ground con trol sta tion set tings
ENABLE
LOWER
BOOM
ENABLE
PLATFORM
FUEL
ON
OFF
ON
ELECTRIC
BASE
Figure 11.5 - Ground Control Box, Electric
Controls
1. The Emergency Stop switch
(ON) (see Figure 11.5).
2. The Platform/Ground Selector switch
(see Figure 11.5) must be set to
PLATFORM.
Platform Control Station settings
3. Set the Emer gency Stop switch
(see Fig ure 11.6).
UPPER
BOOM
LOWER
BOOM
SLEW
13371-3 REV A
FUEL
ELECTRIC
START
Figure 11.6 - Platform Control Box, Electric
Controls
MHP15/44HD V2 – 13620-1
LIFT
SLEW
BOOMS
STABILISER
START
CHOKE
must be
to ON
LIFT
ENABLE
lb
kg
JIB
BOOM
ROTATE
PLATFORM
SPEED
13371-2
CHOKE
EMERGENCY LOWER
ENABLE
11. Emergency Operation
IMPORTANT
The EPV16 has an ENABLE switch fitted to
the Upper & Lower control boxes. (see
Chapter 6 for a full explanation of the
operation of this switch).
Some machines may also be fitted with a
FOOT OPERATED ENABLE switch.
On those machines fitted with the foot
switch option, both the switch on the control
box and the foot switch perform the same
function.
If the FOOT OPERATED ENABLE SWITCH
op tion is in stalled on your ma chine go to
Step 4 - oth er wise go to Step 5.
Figure 11.7 - Enable Switch (Foot)
4. Step on the plat form foot switch
Fig ure 11.7).
Go to Step 6.
5. Op er ate the En able switch
switch down and hold it down .
6. Whilst still operating the enable switch, press
and hold the Emergency Lower switch
down and the upper boom will begin
lowering.
7. To op er ate other func tions dur ing the
emer gency lower the fol low ing switches must
be op er ated to gether.
En able
or
Emer gency Lower
As soon as these switches are op er ated the
up per boom will be gin de scend ing. If an other
func tion is de sired it must be se lected be fore
the boom has reached the rest po si tion
e.g. Up per or Lower Boom
NOTE:
When emer gency low er ing, it is only pos si ble to
Slew or lower the Jib Boom whilst the Up per
boom is low er ing.
Rev B
(see
by press ing the
(foot switch - Fig ure 11.7)
or
Slew
page 11 - 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhp1544hd

Table of Contents