RCD/ELCB Outlet (option)

Figure 6.1 - RED/ELCB Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at
the base and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let.
To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
base.
If the prob lem per sists call a trained ser vice tech ni -
cian.

Stabilisers

Figure 6.3 - Stabilisers
The MHP15/44HD V2 booms can not be raised un -
less the sta bi lis ers are set and the lift en able light on
the lower con trol box is lit. Once the booms are
raised from the stowed po si tion the sta bi lis ers be -
come dis abled un til the booms are stowed in the
travel po si tion.
MHP15/44HD V2 – 13620-1

6. Shut-offs and Circuit Breakers

Electrical Circuit Protection

There is only one (1) fuse, on a stan dard
MHP15/44HD V2, that is ac ces si ble to the op er a -
tor. Its pur pose is to pro tect the elec tri cal cir cuits
from elec tri cal over loads. When the fuse blows re -
place it with an iden ti cally rated fuse. If the fuse
blows a sec ond time, take the MHP15/44HD V2 out
of ser vice and re fer the prob lem to a qual i fied
trained ser vice tech ni cian for re pair.
Rev B
page 6 - 1