Safety - Low Voltage Insulation; Owner Responsibility; Insulation Maintenance; Electrical Safety Certificate - Snorkel MHP15HD Operator's Manual

Table of Contents

Advertisement

The low volt age(LV) in su lated MHP15/44HD V2 is
in su lated to 1000V AC or 1500V DC.
IMPORTANT
If you have not yet read Chapter 1 "Safety"
then do so now before you read this chapter.
This chapter deals only with safety issues
s p e c i f i c a l l y r e l a t e d t o o p e r a t i n g a n
MHP15/44HD V2 with low voltage insulation.
Chapter 1 covers all other aspects involved
in the safe operation of an MHP15/44HD V2
and is essential reading.
This chap ter does not set out to pro vide any de tail
on the safety is sues or reg u la tions con cerned with
the op er a tion of a low volt age in su lated
MHP15/44HD V2 around live conductors.
This chap ter is sim ply in tended to alert the op er a tor
to gen eral safety is sues as so ci ated with an LV in -
su lated ma chine.

Owner Responsibility

As stated previously in this manual, providing
the operator with safety information and/or
training on standards, codes of practice and
local authority regulations concerning the
operation of this machine is the responsibility
of the owner of the machine.

Insulation Maintenance

WARNING
The maintenance of the insulation is
critically important to maintaining the
insulation rating of the LV MHP15/44HD V2.
The following are given as general guidelines for
ensuring the maintenance of the insulation system.
The is sues that are within the scope of the op er a tor
are cov ered in Chap ter 9 "Pre-Op er a tional In spec -
tion".
1. Inspection of the interior and exterior
insulator surfaces for signs of damage, which
may lead to a reduction in dielectric
properties.
2. Inspection of cover insulation for signs of
cracking or corrosion.
DANGER
Never use a LV MHP15/44HD V2 that has any
damage to any of the insulator surfaces or
covers.
MHP15/44HD V2 – 13620-1

2 Safety - Low Voltage Insulation

The cleanliness of the insulator surfaces are
imperative to the correct functioning of the
insulator.
Failure to maintain the cleanliness of the
insulator could lead to insulator failure and
death or serious injury.
3. Before using the machine the insulator
surfaces shall be dry, and free from all road
grime, dirt, dust and other contaminants.
When the insulator surfaces require cleaning
they should be washed with a mild detergent
suitable for fibreglass that leaves no residue
and water.
After washing, the insulator should be dried
with a soft lint free cloth.
Avoid the use of high pressure water blast at
close range on the insulator surface as this
may drive contaminanta into the surface.
4. A regular maintenance scheme should be
developed to ensure the insulator surface is
easy to clean and retains the hydrophobicity
required e.g. silicon free waxes.
5. Inspection and replacement as required of all
insulation markers or signs (decals - see
below).

Electrical Safety Certificate

All LV ma chines are re quired to carry a cer tif i cate
of elec tri cal safety. Op er a tors should en sure that
there is a cur rent elec tri cal safety certificate for the
ma chine they are us ing.
Never use a LV Insulated MHP15/44HD V2
that does not have a current certificate of
electrical safety.

Insulation Covering Test

Re fer to the Chap ter "In su la tion Test - LV Ma -
chines" in the Re pair Parts man ual for de tails con -
cern ing this test.

Basket Emergency Exit

The LV MHP15/44HD V2 fibre glass bas ket is fit ted
with an es cape hatch in the form of a sep a rate
panel at the rear of the bas ket.
Rev B
DANGER
DANGER
page 2 - 11