A bub ble level is lo cated on the trailer side rail, be -
side the out rig ger con trols. Watch the bub ble level
while you set the sta bi lis ers. Lower the sta bi lis ers,
one (1) at a time, just enough to cen ter the bub ble
in the cir cle on top of the guage. When the bub ble is
cen tered the plat form is level and can be safely
raised.

RCD/ELCB AC outlet

Power Input
Connector
At Base
Figure 3.17 - RCD/ELCB AC Outlet
The RCD (Re sid ual Cur rent De vice) is lo cated at
the base and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let. To re set the out let dis con nect the power tool
lead from the plat form box and re set the RCD at the
base. If the prob lem per sists call a trained ser vice
tech ni cian.

Sta bi liser/Boom In ter lock Test

All ma chines in the Snor kel 'EPV' Se ries of Truck
Mounted El e vat ing Work Plat forms are fit ted with a
very im por tant safety fea ture, a 'Sta bi liser/Boom
In ter lock' sys tem that pre vents the booms be ing el -
e vated to an un safe po si tion un less all four sta bi lis -
ers have been cor rectly set and have made firm
con tact with the ground.
This same safety fea ture also pre vents the Sta bi lis -
ers be ing op er ated while ei ther or both Booms are
el e vated.
IMPORTANT
The cor rect op er a tion of the Sta bi liser/Boom
In ter lock is crit i cal to en sure that the MHP is
op er ated safely and with out risk.
De tailed in struc tions on how to carry out a test to
en sure that this func tion is work ing cor rectly are
pro vided at the be gin ning of the Pre-Op er a tional
In spec tion chap ter in this man ual.
MHP15/44HD V2 – 13620-1

Flashing light (Option)

The flashing light alerts people that the
MHP15/44HD V2 is moving. The light flashes at
about one (1) flash per second any time the
MASTER KEY switch is on. There is no ON/OFF
switch for the flashing light, it cannot be turned off
while the MHP15/44HD V2 is running.
RCD At Base
Power Outlet
At Platform
Rev B
3. Safety Devices
page 3 - 5