Technical Data; Operating Environments; Technical Data 230V - Fronius AccuPocket 150/400 TIG Operating Instructions Manual

Hide thumbs Also See for AccuPocket 150/400 TIG:
Table of Contents

Advertisement

Technical data

Operating envi-
ronments
Technical data
230V
76
Transport, storage or operation of the charger outside the stipulated area will
be deemed improper. The manufacturer shall not be held liable for any dam-
age arising from such usage.
Ambient temperature range:
-
during operation: -10 °C to +40 °C (14 °F to 104 °F)
-
during transport and storage: -20 °C to +55 °C (-4 °F to 131 °F)
-
recommended temperature range during charging: + 4 °C to + 40 °C (+
39,2 °F to + 104 °F)
Relative humidity:
-
up to 50 % at 40 °C (104 °F)
-
up to 90 % at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or sub-
stances, etc.
Can be used at altitudes up to 2000 m (6561 ft.)
Mains voltage
Mains frequency
Mains current
Mains fuse
Efficiency
Effective power
Apparent power
Power consumption (standby)
Protection class
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
EMC emission class
Mark of conformity
Output voltage range
Output current
Output power
Cooling
Dimensions l x w x h
Weight (without cable)
Protection class
Overvoltage category
Device may only be operated on neutral-earthed
systems.
~ 230 V AC, ±15%
50 / 60 Hz
max. 9.5 A eff.
max. 16 A
max. 95%
max. 1100 W
max. 2370 VA
max. 2.1 W
I (with PE conductor)
none
A
CE
30 - 58 V DC
max. 18 A DC
max. 1040 W
Convection and fan
270 x 168 x 100 mm
approx. 2 kg
IP43S
II

Advertisement

Table of Contents
loading

This manual is also suitable for:

Activecharger 1000

Table of Contents