Vrd Safety Device (Optional); General; Function - Fronius AccuPocket 150/400 TIG Operating Instructions Manual

Hide thumbs Also See for AccuPocket 150/400 TIG:
Table of Contents

Advertisement

VRD safety device (optional)

General

VRD is an additional safety device that prevents, as far as possible, output voltages that
may pose a danger to persons.
VRD = Voltage Reduction Device.

Function

VRD is active
VRD is not active
54
NOTE! Within 0.3 seconds of the end of welding:
-
VRD is active again
-
The output voltage is limited to 14 V again
The welding circuit resistance is greater
than the minimum human body resistance
(greater than or equal to 200 Ohm):
-
VRD is active
-
Open circuit voltage is limited to 14 V
-
The VRD indicator lights up
-
Example: no risk ensues if both wel-
ding sockets are touched accidentally
at the same time.
The welding circuit resistance is less than
the minimum human body resistance (less
than 200 Ohm):
-
VRD is inactive
-
Output voltage not limited in order to
ensure sufficient welding power
-
The VRD indicator does not light up
-
Example: Start of welding

Advertisement