Parameters Of The Expert Level With Diagnostics And Test - Siemens KNX RDG400KN Basic Documentation

Room thermostats with communications
Hide thumbs Also See for KNX RDG400KN:
Table of Contents

Advertisement

Name
Expert level
P30
Heat P-band Xp/switching diff
P31
Cool P-band Xp/switching diff
P32
Radiator P-band Xp/swi diff
P33
Dead zone Comfort mode
P35
Integral action time Tn
RDG400KN
RDG405KN
P36
H/C ch'over swi point cooling
P37
H/C ch'over swi point heating
P38
Input X1
RDG400KN
(range 0..3 [ECO]..8)
RDG405KN
(range 0..3 [PROT]..10)
P39
Normal position input X1
P40
Input U1
P42
Input D1
RDG400KN
(range 0..3 [ECO]..7)
RDG405KN
(range 0..3 [PROT]..10)
P43
Normal position input D1
P44
Actuator running time Y1/Y2
P46
Output Y1/Y2
P47
Controller output VAV
P51
Flow temp limit floor heating
P54
Fan overrun time
P63
Supply air limit value min
P64
Supply air limit value max
P65
Protection heating setpoint
P66
Protection cooling setpoint
P68
Temporary Comfort mode
P69
Temporary Comfort setpoint
68 / 86
Siemens
Smart Infrastructure
3.13.4 Parameters of the Expert
level with diagnostics and
test
Factory setting
2 K
1 K
2 K
2 K
5 min
45 min
16 °C
28 °C
1: = Ext. sensor
0 (NO)
0
3 =
Operating mode
contact (RDG400KN)
Window contact
(RDG405KN
0 (N.O.)
150 s
On/Off (1)
0 = DC 0...10 V
Off
60 s
0%
100%
8 °C
Off
0 (= Off)
Off
RDG400KN,RDG405KN Basic documentation
Range
0.5...6 K
0.5...6 K
0.5...6 K
0.5...5 K
0...10 min
0...120 min
10...25 °C
27...40 °C
0 = --- (no function)
1 = Room temp ext. sensor/
return air temp (AI)
2 = H/C changeover (AI/DI)
3 = Operat. mode contact [ECO],
window contact [PROT] (DI)
4 = Dewpoint sensor (DI)
5 = Enable electric heater (DI)
6 = Fault input (DI)
7 = Monitoring input (Digital)
8 = Monitoring input (Temp)
10 = Presence detector (DI)
0 = Normally open/open
1 = Normally closed/close
0 = No function
1 = Input for air damper position
2 = input CO
sensor
2
0 = --- (no function)
2 = H/C changeover (DI)
3 = Operat. mode contact [ECO],
window contact [PROT] (DI)
4 = Dewpoint sensor (DI)
5 = Enable electric heater (DI)
6 = Fault input (DI)
7 = Monitoring input (Digital)
10 = Presence detector (DI)
0 = Normally open/open
1 = Normally closed/close
20...300 s
0 = 3-position
1 = 2-position - ON/OFF
2 = 2-position - PWM
0 = DC 0...10 V
1 = 3-position
Off, 10...50 °C
0...360 s
0...P64 (%)
P63...100 (%)
OFF, 5...WCoolProt;
WCoolProt = 40 °C max.
OFF, WHeatProt... 40;
WHeatProt = 5°C min.
0...360 min
OFF = Disabled
ON = Enabled
ü
ü
ü
ü
ü
ü
Appl
ü
ü
Appl
ü
ü
P46, P47
ü
ü
P38
ü
ü
P38
ü
ü
ü
ü
P38
X
ü
ü
ü
ü
ü
P42
ü
ü
P46
ü
ü
Appl
ü
ü
Appl
ü
ü
P38
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
P02
ü
ü
CE1P3192en
2019-04-12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Knx rdg405kn

Table of Contents