Download Print this page
Carlisle BINKS 85-214 Service Manual

Carlisle BINKS 85-214 Service Manual

1/4" air pressure regulator

Advertisement

Quick Links

SERVICE MANUAL
EN
Flow Coefficient (Cv) .60 Maximum
1
2
3
4
5
6
7
1
85-192
2
85-305
3
20-3635
Screw No.10-24 x 1/2 Socket Head
4
85-304
5
85-193
6
85-306
n
7
85-194
8
20-2227
n s
85-301
9
85-303
10
85-341
n
11
85-309
12
85-196
n
77-1890-R15 (1/2021)
BINKS MODEL 85-214 & 85-215
1/4" AIR PRESSURE REGULATOR
!
Do not immerse body in a caustic material.
O-ring (20-2227) can be removed with a
pointed instrument before soaking in
solvent. Install a new o-ring.
PARTS LIST
Knob
Spring
Bonnet
Disc
Diaphragm
Seat
O-Ring
Body (For Model 85-214)
Body (For Model 85-215)
Seat (Buna-N, Standard)
Valve
SPRING
CAUTION
1
Ref.
Replacement
1
No.
Part No.
4
13
85-310
n
1
14
20-4407
n
1
15
85-336
1
• Not sold separately.
1
n Also available in Repair Kit 6-207. Please order separately.
1
s Available in package of 5 pcs. 20-2227-5.
1
1
1
1
1
1 / 4
8
9
10
11
12
13
14
15
Ind.
Description
Parts
Req'd.
SCREEN
1
SEAL
1
CAP
1
www.carlisleft.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the BINKS 85-214 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carlisle BINKS 85-214

  • Page 1 SERVICE MANUAL BINKS MODEL 85-214 & 85-215 1/4" AIR PRESSURE REGULATOR Flow Coefficient (Cv) .60 Maximum CAUTION Do not immerse body in a caustic material. O-ring (20-2227) can be removed with a pointed instrument before soaking in solvent. Install a new o-ring. PARTS LIST 85-192 Knob...
  • Page 2 In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: WARNING NOTE CAUTION Hazards or unsafe practices which Hazards or unsafe practices which could result in severe personal Important installation, operation or could result in minor personal injury, injury, death or substantial property maintenance information.
  • Page 3 IDENTIFICATION OF AIR REGULATOR PORTS 1/4 NPT Regulated Port 1/4 NPT Regulated Port 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT Inlet Port Regulated Port 1/4 NPT Regulated Port Mainline 1/4 NPT Regulated Port Inlet Port Outlet or By-Pass 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT...
  • Page 4 This product is covered by Carlisle Fluid Technologies’ materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Carlisle Fluid Technologies, will void all warranties. Failure to reasonably follow any maintenance guidance provided may invalidate any warranty.

This manual is also suitable for:

Binks 85-215