1. Remove all loads from the output end
2. Rotate the 3 in 1 Control Knob to the "Choke" position。
3. Turn the AC Protector/Breaker to "Off"
4. Press the "On" button
5. After starting the engine, set the 3 in 1 Control Knob to
the "Run" position
6. To use electrical equipment, AC circuit breaker protector
should be placed in "On" position
Do not hold the 3 in 1 Control switch in the electric starting
position for more than 5 seconds, otherwise it could
damage the starter motor. If starting is unsuccessful, wait
10 seconds before attempting to start again.
If the speed of the starter motor decreases after several
attempts, it means that the battery should be charged