Figure 6-15
6.6.2 Fence/miter slot parallelism
See Figure 6-16.
1.
Place fence on table. Slide it over until left
edge (A) lines up with right miter slot (B), and
lock fence.
2.
The locked fence must be even (parallel) with
miter slot from front to back.
3.
If fence is not even along length of miter slot,
unlock and remove it from guide rail (Figure
17).
4.
Adjust one of two setscrews (C, Figure 6-17)
with 5mm hex wrench until fence is even with
miter slot edge along its entire length when
locked.
Note: You may need to re-adjust clamping
pressure (described below) after aligning fence.
Figure 6-16
Figure 6-17
6.6.3 Clamping pressure adjustment
The
Accu-Fence
manufacturer to lock securely when handle is
pushed down. If adjustment is needed:
1.
Unlock fence and remove it from guide rail.
2.
Adjust each of two setscrews (C, Figure 6-17)
exactly the same number of rotations until
fence is held securely when handle is pushed
down.
Clockwise rotation of setscrews will increase cam
pressure. Counterclockwise rotation will decrease
cam pressure.
6.6.4 90 to table adjustment
1.
Place fence on saw table and lock it.
2.
Place a square (D, Figure 6-16) on table next
to fence. Fence should be 90 to table.
3.
If adjustment is necessary, unlock fence, and
turn one of two nylon adjustment screws (E,
Figure 6-16) until fence is 90 to table.
4.
Lock fence and verify the adjustment.
6.6.5 Cursor adjustment
1.
Disconnect table saw from power source.
2.
Remove blade guard and raise blade above
tabletop.
3.
Unlock fence and slide it to approximately 4-
inches from saw blade. Lock fence.
4.
Measure distance between saw blade and
inside of fence. Note: Measure from a tooth
edge, not the flat side of the blade.
5.
Adjust cursor (F, Figure 6-16) to read the
distance just measured, and tighten cursor
assembly to fence.
6.
Take a test cut and confirm that the
adjustment is correct.
Note: Slots in cursor should allow enough
adjustment travel. If cursor lacks enough travel to
give correct measurement, loosen guide tube and
adjust as needed. If you still cannot achieve correct
measurement, loosen front rail and adjust as
needed. If you have to adjust front rail, you will
need to go through front rail assembly instructions
again.
Cursor position should be checked after installing a
new blade.

6.7 Side plate replacement

The Accu-Fence is specially designed to save
many hours of down-time when side plates need to
be replaced. In an operation that can last an entire
day with other fences, the Accu-Fence side
replacement takes only a few minutes.