2.5.3
Terminal layout of the main circuit terminals,
wiring of power supply and the motor
 Terminal layout
Converter unit
N/-
R/L1 S/L2
NOTE
• Make sure the power cables are connected to the R/L1, S/L2, and T/L3. (Phase need not be matched.) Never connect the
power cable to the U, V, and W of the inverter. Doing so will damage the inverter.
• Connect the motor to U, V, and W. (The phases must be matched.)
42
2. INSTALLATION AND WIRING
2.5 Main circuit terminals
To inverter
P/+
Charge lamp
Jumper
T/L3
Power supply
Inverter
To converter
unit
N/-
M
Motor
P/+
Charge lamp
Jumper

Advertisement

Table of Contents
loading

Table of Contents