• 575 VAC power input
Inverter
Model
Rating
FR-A872-05690-P
ND
FR-A872-06470-P
ND
FR-A872-07150-P
ND
NOTE
• When the wiring length from a unit to the node point is less than 10 m, a balance reactor (FR-POL) is required.
 Selecting the breaker / magnetic contactor
Check the model name of the inverter and the converter unit you purchased. Appropriate peripheral devices must be selected
according to the capacity.
Refer to the following table to prepare appropriate peripheral devices.
• One circuit breaker and one magnetic contactor in total in a system
Motor output
Number of
(kW)
units
710
2
800
2
900
2
1000
3
1200
3
1300
3
*1
Selection when using a 4-pole standard motor.
*2
Select an MCCB according to the power supply capacity.
MCCB
Converter unit
Converter unit
*3
The matrix shows the magnetic contactor selected according to the standards of Japan Electrical Manufacturers' Association (JEM standards)
for AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the MC is used for emergency stops during motor driving,
the electrical durability is 25 times.
• One circuit breaker and one magnetic contactor per converter unit
Motor output
Number of
(kW)
units
710
2
800
2
900
2
1000
3
1200
3
1300
3
*1
Selection when using a Mitsubishi 4-pole standard motor.
*2
Select an MCCB according to the power supply capacity.
MCCB
MCCB
*3
The matrix shows the magnetic contactor selected according to the standards of Japan Electrical Manufacturers' Association (JEM standards)
for AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the MC is used for emergency stops during motor driving,
the electrical durability is 25 times.
Converter unit
Balance reactor
FR-CC2-N450K-P
FR-CC2-N500K-P
FR-POL-N560K
FR-CC2-N560K-P
Applicable converter
*1
model
FR-CC2-N450K-P
FR-CC2-N500K-P
FR-CC2-N560K-P
FR-CC2-N450K-P
FR-CC2-N500K-P
FR-CC2-N560K-P
INV
M
INV
Applicable converter
*1
model
FR-CC2-N450K-P
FR-CC2-N500K-P
FR-CC2-N560K-P
FR-CC2-N450K-P
FR-CC2-N500K-P
FR-CC2-N560K-P
Converter unit
INV
M
Converter unit
INV
Number of units
connected in
parallel
2
3
2
3
2
3
*1*2
MCCB
or earth leakage circuit
breaker (ELB)
1000 A
1200 A
1500 A
1500 A
1600 A
1800 A
*1*2
MCCB
700 A
800 A
800 A
700 A
800 A
800 A
600 V system capacity
Motor capacity
Output current
(kW)
(A)
560
819
800
1228
630
910
900
1365
710
1035
1100
1552
Magnetic contactor
*1*3
(MC)
on converter unit's
input side
900 A
1000 A
1100 A
1300 A
1400 A
1600 A
Magnetic contactor
*1*3
(MC)
on converter unit's
input side
660 A
660 A
800 A
660 A
660 A
800 A
2. INSTALLATION AND WIRING
2.1 Peripheral devices
1
2
3
4
5
6
7
8
9
10