Electrode Maintenance
1. Rinse the electrode with tap water or electrode storage solution after each
measurement.
2. In aggressive chemicals, dir ty or viscous solutions, and solutions with heavy
metals or proteins, take readings quickly and rinse electrode immediately afterward.
3. If possible, keep a small piece of paper or sponge in the electrode cap – moistened
with clean water or electrode storage solution (NOT de-ionized water) – and close
the cap over the electrode.
Changing Batteries
1. Open battery compartment lid (with attached lanyard loop).
2. Remove old batteries; replace with fresh ones. Note polarity.
(shown in diagram below)
Self-Diagnostic Messages
3 Bars indicates Battery is full (100%)
2 Bars indicates 50% of the battery life is left
Low battery
indicator
1 Bar indicates 25% of the battery life is left
Blinking battery casing indicates the need to replace
batteries with fresh ones as specified by manufacturer
Electrode is not in contact with solution or electrode
Over range /
is failing
Or / Ur
Or / Ur
Or / Ur
Or / Ur
Or / Ur
Under range
signal
Replacement sensor is not connected properly to the
tester during sensor replacement
Error
mV calibration error while attempting to calibrate tester to a
E r E r E r E r E r. 0 . 0 . 0 . 0 . 0
M e s s a g e
value which is out of range
Electrode Replacement
You can replace the electrode module at the fraction of the cost of a new tester.
When the tester fails to calibrate or gives fluctuating readings in calibration standards,
you need to change the electrode.
1. With dry hands, grip the ribbed tester collar with electrode facing you. Twist
the collar counter clockwise (see picture A). Save the ribbed tester collar and
O-ring for later use.3. Align the four tabs on the new module so that they
match the four slots on the tester (see picture B).
2. Pull the old electrode module away from the tester.
3. Align the four tabs on the new module so that they match the four slots on the
tester (see picture B).
Rotate collar
away from you
Rlbbed collar
Insert Electrode Module
Electrode Module
Small O-ring
Small Tab
Large Tab
4. Gently push the module onto the slots to sit it in position. Push the smaller
O-ring fully onto the new electrode module. Push the collar over the module
and thread it into place by firmly twisting clockwise.
Note: It is necessary that you recalibrate your tester prior to measurement after an
electrode replacement.
Applications
Water quality testing • pools • spas • cooling towers • water purification • chromate
reduction • cyanide oxidation • boilers • pulp bleaching • ozone systems • water and
wastewater treatment • and more!
Warranty
The waterproof ORPTestr10DJ and ORPTestr10BNC are warranted to be free from
manufacturing defects for 2 years and electrode module for 6 months. If repair, adjustment
or replacement is necessary and has not been the result of abuse or misuse within the
time period, please return the tester – freight prepaid – and correction will be made
without charge. Out of warranty products will be repaired on a charge basis.
Return of Items
Authorization must be obtained from your distributor before returning items for any
reason.
When applying for authorization, please include information regarding the reason the
item(s) are to be returned.
Note: We reserve the right to make improvements in design, construction and appearance
of products without notice. Prices are subject to change without notice.
S p e c i f i c a t i o n s
S p e c i f i c a t i o n s
S p e c i f i c a t i o n s
S p e c i f i c a t i o n s
S p e c i f i c a t i o n s
Large Screen Tester
Large Screen Tester
Large Screen Tester
Large Screen Tester
Large Screen Tester
Range
Resolution
Large
O-ring
Accuracy
Calibration Window
Auto Off
User Reset
Non Volatile Memory Backup
LCD Display
Power Requirement
Battery Life
Operating Temperature
Tester Dimension
Weight
Visit us at www.TestEquipmentDepot.com
ORPTestr10 / ORP Testr 10BNC
ORPTestr10 / ORP Testr 10BNC
ORPTestr10 / ORP Testr 10BNC
ORPTestr10 / ORP Testr 10BNC
ORPTestr10 / ORP Testr 10BNC
-999 mV to +1000 mV
1 mV
±2 mV
Offset adjustment up to ± 150mV
After 8.5 minutes from last key press
Yes
Yes
Dual
4 x 1.5V "A 76" micro Alkaline Batteries
More than 500 hours
0 – 50 °C
6.5 "L x 1.5"dia. (165 x 38 mm)
Boxed: 220 x 60 x 50 mm
3.25 oz (90 gm)
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
68X068043 01/04 Rev 0

Advertisement

loading

This manual is also suitable for:

Orptestr10bncWd-35650-14