Operational Problems - Heta Scan-Line 7 Series Operating And Installation Instructions

Hide thumbs Also See for Scan-Line 7 Series:
Table of Contents

Advertisement

Take care when emptying the ash pan, as cin-
ders can continue to burn in the ash for long
periods of time.
Stove data table in accordance with eN 13240 testing
Stove
Nominal
fluegas
type
Scan-Line
tempera-
series
ture c°
7 B
237
7 C
237
7 D
237
The nominal output is the output to which the stove has been tested.
The test was carried out with the secondary air 50% open.

OPeRATIONAL PRObLeMS

The chimney must be swept at least
once a year, we recommend the use
of a NACS (national association of
chimney sweeps) registered chim-
ney sweep. In the event of smoke or
malodorous fumes being produced,
you must first check to see whether
the chimney is blocked. The chim-
ney must, of course, always provide
the minimum draught necessary to
ensure that it is possible to regulate
the fire. Please note, however, that
chimney draft is dependent on the
weather conditions. In high winds, the
draft can become so powerful that it
may be necessary to fit a damper in
the flue gas pipe to regulate the draft.
When cleaning the chimney, soot and
other deposits may come to fall on the
Smo-
Fuel
Draught
ke
vo-
min
stub
lume
mm
kg
mbar
ø150
1
0.12
ø150
1
0.12
ø150
1
0.12
Nominal
Heat
Distance to flamma-
output
output
ble materials in mm
tested
behind
kW
kW
the stove
4
83.1
100
4
83.1
-
4
83.1
100
smoke turning plate. In cases where
the wood burns too quickly, this may
be due to excessive chimney draught.
You should also check to make sure
that the door seal is intact and cor-
rectly fitting.
If the stove it generating too little heat,
this may be because you are firing
with wet wood. In this case, much of
the heating energy is used to dry the
wood, resulting in poor heating eco-
nomics and an increased risk of soot
deposits in the chimney.
Check whether the air holes in the
stones are blocked with for example
ashes etc. Below the casted shaking
grate is it possible to clean the air
channel for the start-up airflow.
Distance to
furnitures
at the
from the
sides
stove in mm
100
800
100
800
100
800
Stove
weight
kg
93
90
100
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scan-line 7bScan-line 7cScan-line 7d

Table of Contents