1. INSTALLATION
7. Fasten the antenna unit to the mounting location with the three sets of supplied
upset screws (M520, flat and spring washers attached) from the bottom through
the mounting holes at step 2. After fastening the screws, coat the screw heads
with the supplied adhesive.
Note: Screw length is dependent on the thickness of the mounting platform.
1.3
Pole Mount
Combine the antenna unit with the pole mount kit then attach the antenna unit assem-
bly to the mounting pole.
1.3.1
Installation notices
• The diameter of the mounting pole must be 25 to 50 mm.
• Use the supplied pole mount kit and the supplied fixing support fixture for the pole
mount installation so that the bow mark of the antenna unit faces to the bow.
• Select the correct clamp size of the pole mount kit fixture considering the diameter
of the mounting pole.
Name
Hose Clamp
1-4
Adhesive
Antenna unit
Pole Mount
Assembly
Antenna cable
Mast diameter
For 20A to 25A (25 to 35 mm)
For 32A to 40A (35 to 50 mm)
Thickness
(mounting plate)
2 to 10 mm
Otherwise
M5 upset screw,
w/flat and spring
washers (3 places)
Anchor point
Mounting
Mounting
pole
pole
Standard supply with CP20-04603
Optional supply (OP20-52).
Length of
M5 screw
20 mm
(supplied)
thickness + 8
to 16 mm
(local supply)
Fixing Support
Fixture
Hose Clamp
Remarks