Rigging; Connection With The Mains - SHOWTEC 60413 Manual

Table of Contents

Advertisement

Mirrorball 10 cm

Rigging

Please follow the European and national guidelines concerning rigging, trussing and all
other safety issues.
Do not attempt the installation yourself !
Always let the installation be carried out by an authorized dealer !
Procedure:
If the device is lowered from the ceiling or high joists, professional trussing systems have to be used.
The device must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net or
a safety cable.
Make sure that the installation area can hold a minimum point load of 10 times the device's load
(e.g. maximum load: 10 kg = point load: 100 kg).
When rigging, derigging or servicing the device, always make sure, that the area below the
installation place is blocked and staying in the area is forbidden.
Improper installation can cause serious injuries and/or damage of property!

Connection with the mains

Connect the device to the mains with the power-plug.
Always check if the right color cable is connected to the right place.
International
L
N
YELLOW/GREEN
Make sure that the device is always properly connected to the earth!
Improper installation can cause serious injuries and/or damage of property!
Ordercode: 60413
EU Cable
UK Cable
BROWN
BLUE
BLACK
GREEN
US Cable
RED
YELLOW/COPPER
SILVER
GREEN
4
Pin
PHASE
NEUTRAL
PROTECTIVE
GROUND