8. Technical Specifications

MultiPlus-II
PowerControl & PowerAssist
Transfer switch
Maximum AC input current
INVERTER
DC Input voltage range
Output when in inverter mode
Cont. output power at 25°C (3)
Cont. output power at 25°C
Cont. output power at 40°C
Cont. output power at 65°C
Maximum apparent feed-in power
Peak power
Maximum efficiency
Zero load power
Zero load power in AES mode
Zero load power in Search mode
Maximum output current
CHARGER
AC Input
Charge voltage 'absorption'
Charge voltage 'float'
Storage mode
Maximum battery charge current (4)
Battery temperature sensor
GENERAL
Auxiliary output
External AC current sensor (optional)
Programmable relay (5)
Protection (2)
VE.Bus communication port
General purpose com. port
Remote on-off
Operating temperature range
Humidity (non-condensing)
ENCLOSURE
Material & Colour
Protection category
Battery-connection
120/240 V AC-connection
Page 26
MultiPlus-II 12V/24V/48V 3kVA 120V
12/3000/120-50
9,5 – 17 V
Output voltage: 120 VAC ± 2%
Frequency: 60 Hz ± 0,1% (1)
93%
13 W
9 W
3 W
85 A peak, 70Arms for 1sec.
Single phase: 90-140 VAC 45 – 65 Hz
14.4 V
13.8 V
13.2 V
120 A
For parallel, split phase and three phase operation, remote monitoring
-40 to +65°C (-40 - 150°F) fan assisted cooling
M8 bolts
Screw terminals 13 mm² (6 AWG)
24/3000/70-50
48/3000/35-30
Yes
50 A
50 A
19 - 33 V
3000 VA
2400 W
2200 W
1700 W
2500 VA
5500 W
94%
13 W
9 W
3 W
28.8 V
27.6 V
26.4 V
70 A
Yes
Yes (32 A)
100 A
Yes
a – g
and system integration
Yes, 2x
Yes
max 95%
Steel, blue RAL 5012
IP22
M8 bolts
Technical Specifications
38 - 66 V
95%
11 W
7 W
2 W
57.6 V
55.2 V
52.8 V
35 A
M8 bolts

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multiplus-ii 12/3000/120-50Multiplus-ii 48/3000/35-30