4. Technical specifications

MultiPlus
PowerControl / PowerAssist
AC input
Maximum feed through current
Minimum AC supply current capacity for
PowerAssist (A)
Input voltage range (V DC)
Output
(1)
Cont. output power at 25°C / 77°F (VA)
Cont. output power at 25°C / 77°F (W)
Cont. output power at 40°C / 104°F (W)
Cont. output power at 65°C / 150°F (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
Zero-load power in AES mode (W)
Zero-load power in Search mode (W)
Maximum output current
AC Input
Charge voltage 'absorption' (V DC)
Charge voltage 'float' (V DC)
Storage mode (V DC)
Charge current house battery (A) (4)
Charge current starter battery (A)
Battery temperature sensor
Auxiliary output
Programmable relay
(5)
Protection
(2)
VE.Bus communication port
General purpose comm. port
Common Characteristics
Common Characteristics
Battery-connection
120V AC-connections
Weight (kg)
Dimensions (hxwxd in mm)
Safety
Emission / Immunity
Automotive Directive
1) Can be adjusted to 50Hz;
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 120VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25°C ambient
5) Programmable relay which can be set for general alarm, DC undervoltage or genset start/stop function
14
12/3000/120-50 120V
Input voltage range: 95-140VAC; Input frequency: 45 – 65Hz; Power factor: 1
INVERTER
9,5 – 17
Output voltage: 120 VAC ± 2%
3000
(3)
2400
2200
1700
6000
93
20
15
8
CHARGER
Input voltage range: 95-140VAC
14,4
13,8
13,2
120
GENERAL
Max. 32A Switches off when no external AC source available
For parallel and three phase operation, remote monitoring and system integration
Operating temp.: -40 to +65°C/ -40 - 150°F (fan assisted cooling)
ENCLOSURE
Material & Colour: aluminium (blue RAL 5012)
STANDARDS
Yes
50
7,5
Frequency
64A peak, 45Arms for 1 sec.
Input frequency: 45 – 65Hz
4
Yes
Yes, 3x
a - g
Yes, 2x
Humidity (non-condensing) : max 95%
M8 bolts (2 plus and 2 minus connections)
Screw terminals 13mm² (6 AWG)
19
362 x 258 x 218
UL1741, UL458, EN 60335-1, EN 60335-2-29
EN 55014-1, EN 55014-2, EN 61000-3-3
2004/104/EC
24/3000/70-50 120V
19 – 33
0 Hz ± 0,1%
: 6
3000
2400
2200
1700
6000
94
20
15
10
Power factor: 1
28,8
27,6
26,4
70
Protection category: IP 21