For more error codes see section 7.3
For the latest and most up to date information about the
blink codes, please refer to the Victron Toolkit app.
Click on or scan the QR code to get to the Victron Support
and Downloads/Software page.

3.5. Shut down procedure

To switch the unit off, use the on/off/charger only switch located on the bottom left hand underside of the case. The middle
position of the switch is the OFF position.
To completely de-power the unit, disconnect the DC fuse or turn off the isolation switch, DC contactor or DC circuit breaker,
located between the battery and the DC terminals of the unit. Note that dangerous residual voltages may still exist inside the
product and at its terminals after shutdown. Never open the product casing, or touch bare terminals.
Page 10
MultiPlus-II 12V/24V/48V 3kVA 120V
PowerAssist
The AC input is switched through, but the load requires more
current than the preset maximum input current. The inverter is
switched on to supply the required additional current. The "mains
on" LED is on and the "inverter" LED is blinking.
Operation