Maintenance – Every 2 years / every 500 operating hours
Fig. 100
Fig. 101
Fig. 102
Fig. 103
92
7.
NOTICE!
Components may get damaged!
Use only oil of the permitted specifica-
tion.
Fill in hydraulic oil up to the mark on the steering rod head.
Mark: approx. 40 mm (1.6 in) below the filler opening
8.
Slacken the bleeding screw.
9.
Wait until all air has escaped and then tighten the bleeding
screw.
10.
Fill in hydraulic oil up to the mark on the steering rod head.
11.
Screw in the filler screw.
12.
Dispose of oil in an environmentally friendly way.