8.8 Semi-annually

8.8.1 Battery service

Fig. 64
1
2
3
Fig. 65
Maintenance free batteries also need care. Mainte-
nance free only means that the fluid level does not
need to be checked.
Every battery has a self-discharge, which may, if
B-SYM-1077
not checked occasionally, even cause damage to
the battery as a result of exhaustive discharge.
Exhausted batteries (batteries with formation of
sulphate on the plates) are not covered under war-
ranty!
Protective equipment:
1.
Park the machine safely
in secured condition" on page 57.
2.
Remove the bracket (1) of the battery.
3.
Remove the battery (2) and the vibration damping mats (3).
4.
Check the condition of the vibration insulation mats, replace if
necessary.
5.
Clean the outside of the battery.
6.
Clean the battery poles and terminals and grease them with
pole grease (Vaseline).
7.
On serviceable batteries check the acid level, if necessary
B-692-0123
top up to the filling mark with distilled water.
8.
Install battery and vibration insulation mats.
9.
Install the bracket of the battery.
DRP70D
Maintenance – Semi-annually
n
Working clothes
n
Safety shoes
n
Protective gloves
n
Safety goggles
Ä Chapter 6.4 „Parking the machine
77