Checking And Cleaning The Water Separator - Fayat Group DYNAPAC DRP70D Operating Instruction

Reversible plate
Table of Contents

Advertisement

Fig. 60
Fig. 61

8.7.2 Checking and cleaning the water separator

Fig. 62
7.
Blow the air filter out with dry compressed air (max. 5 bar
(73 psi)) from inside to outside by moving the gun up and
down inside the element, until it is free of dust.
8.
Examine the air filter with a torch for cracks and holes.
9.
Replace the air filter if it is damaged.
10.
Slide the air filter (2 ) carefully into the filter housing.
11.
Check the sealing face (3) on the cover.
12.
Close the cap (1).
The service intervals for the water separator
depend on the water content in the fuel and can
therefore not be determined precisely.
After taking the engine into operation you should
B-SYM-1075
check for signs of water and dirt initially every day.
DRP70D
Maintenance – Weekly
CAUTION!
Danger of eye injuries caused by particles
flying around!
Wear your personal protective equipment
(safety gloves, protective working
clothes, goggles).
NOTICE!
Danger of engine damage!
Ensure correct fit of cover and seal.