Trane XR80 Manual

Upflow/horizontal right or upflow/horizontal left induced draft gas furnace

Advertisement

Upflow/Horizontal Right
or Upflow/Horizontal Left
Induced Draft Gas Furnace
XR 80
TUD040,060,080,100,120,140C
Single-Stage Fan Assisted
Combustion System
PUB. NO. 22-1640-06-0702 (EN)
FURN-PRC001-EN

Advertisement

Table of Contents
loading

Summary of Contents for Trane XR80

  • Page 1 FURN-PRC001-EN Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUD040,060,080,100,120,140C Single-Stage Fan Assisted Combustion System PUB. NO. 22-1640-06-0702 (EN)
  • Page 2: General Features

    General Features Natural Gas Models Air Delivery Central Heating furnace designs are The 4-speed, direct drive blower motor, certified by the American and Canadian has sufficient airflow for most heating and Gas Associations for both natural and cooling requirements, will switch from L.P.
  • Page 3: Table Of Contents

    Contents General Features Features and Benefits Standard Equipment Optional Equipment General Data TUD040C924K TUD040C930K TUD060C924K TUD060C936K TUD080C924K TUD080C936K TUD080C948K TUD080C960K TUD100C936K TUD100C945K TUD100C948K TUD100C960K TUD100C972K TUD120C954K TUD120C960K TUD140C960K Performance Data Field Wiring Twinning Field Wiring Dimensions Electrical Data 22-1640-06-0702 (EN)
  • Page 4: Features And Benefits

    Features and Benefits XR 80 Upflow/Horizontal Right Or Left Standard Equipment • Power supply 115/1/60 • Cleanable high velocity filters • Multi-port In-shot burners • Standard filter sizes • Integrated solid state control with • Single wire twinning self diagnostics •...
  • Page 5: Optional Equipment

    Features and Benefits Optional Equipment Thermostat ................................BAYSTAT388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................BAYSTAT305 [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .............. TAYSTAT300C [ ] Propane Conversion Kit ............................
  • Page 6: General Data

    General Data Product Specifications 1 MODEL TUD040C924K TUD040C930K TUD060C924K TUD060C936K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 40,000 40,000 60,000 60,000 Capacity BTUH (ICS) 3 32,000 32,000 47,000 47,000 AFUE 80.0 80.0 80.0...
  • Page 7: Tud080C924K

    General Data Product Specifications 1 MODEL TUD080C924K TUD080C936K TUD080C948K TUD080C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 80,000 80,000 80,000 80,000 Capacity BTUH (ICS) 3 64,000 63,000 64,000 64,000 AFUE 80.0 80.0 80.0...
  • Page 8: Tud100C936K

    General Data Product Specifications 1 MODEL TUD100C936K TUD100C945K TUD100C948K TUD100C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 100,000 100,000 100,000 100,000 Capacity BTUH (ICS) 3 79,000 79,000 79,000 79,000 AFUE 80.0 80.0 80.0...
  • Page 9: Tud100C972K

    General Data Product Specifications 1 MODEL TUD100C972K TUD120C954K TUD120C960K TUD140C960K TYPE Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal Upflow / Horizontal RATINGS 2 Input BTUH 100,000 120,000 120,000 140,000 Capacity BTUH (ICS) 3 80000 96,000 96,000 111,000 AFUE 80.0 80.0 80.0...
  • Page 10: Furnace Airflow Vs. Static Pressure

    Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 HIGH - Black 1018 1004 MED.-HIGH - Blue TUD040C924K MED.-LOW - Yellow LOW - Red HIGH - Black 1307 1262 1211...
  • Page 11 Performance Data FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 TUD100C972K HIGH - Black 2484 2458 2432 2387 2342 2275 2208 2125 2041 BOTTOM AND MED.-HIGH - Blue LEFT SIDE MED.-LOW - Y ellow NOTE...
  • Page 12: Field Wiring

    Field Wiring Field Wiring Diagram For Heating Only From Dwg. 21B341437 Rev. 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without Transformer) From Dwg. 21B341436 Rev. 1 22-1640-06-0702 (EN)
  • Page 13: Twinning Field Wiring

    Twinning Field Wiring From Dwg. 21B341422 Rev. 1 From Dwg. 21B341423 Rev. 1 22-1640-06-0702 (EN)
  • Page 14: Tud-C Outline Drawing

    TUD-C Outline Drawing (All dimensions are in inches) From Dwg. 21C341699 Rev. 1...
  • Page 15: Gas Furnaces Schematic Diagrams

    Electrical Data Schematic Diagrams for Gas Furnaces From Dwg. 21D341704 Rev. 1 22-1640-06-0702 (EN)
  • Page 16 TUD-D-1 3/98 Stocking Location PI Louisville & Webb/Mason-Houston 7/02 Trane A business of Trane has a policy of continuous product and product data improvement and it reserves the right to change American Standard Companies www.trane.com design and specifications without notice.

Table of Contents