F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n
Table 11. Supply Duct Connections
Upflow Furnace with Coil
Refer to
Step 1. Step 2. Step 3. Step 4.
Furnace in Horizontal Right with "A" Coil
Note: Flat or dedicated horizontal coils may require flanges to be bent
upward.
Refer to
Step 7. Step 5. Step 8. Step 4.
30
Furnace in Horizontal Left with Coil
Refer to
Step 1. Step 5. Step 3. Step 4.
Installation Instructions
1.
Bend furnace flanges up.
2.
Set the coil on top of the furnace.
3.
Screw through the coil cabinet into the furnace flange. Guide
holes are located on the coil.
4.
Seal per local codes and requirements.
5.
Support the furnace and coil independently.
6.
Set the coil on top of the furnace.
7.
Bend furnace flanges down.
8.
Match the coil up flush to the back of the furnace.