E. Wiring the E-60
(Ring
VIKING
connector
included)
** Earth
Ground
(optional)
Green
(Tip)
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet
and the telephone line. It is recommended that a surge protector be installed to protect against such surges.
* Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a
maximum insulation of 0.082 inches. Do not strip wires prior to terminating.
** Note: To increase surge protection, loosen the PCB mounting screw labeled
with ring terminal (included) from the mounting screw to Earth Ground (grounding rod, water pipe, etc.) After
fastening ring treminal to PCB mounting screw, bend terminal up to avoid interference with single gang box.
*** Note: Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking K-1900-5 Dialer (DOD
317) or K-1900-30 Multi-Number Dialer (DOD 300).
**** Note: When installing a line powered phone on a low voltage and/or low loop current phone system extension, a
Viking TBB-1B Talk Battery Booster may be required,see DOD 632.
A. Adjusting Speaker Volume
The speaker volume pot can be adjusted to increase or decrease the speaker volume to the level
desired.
B. Adjusting the Microphone Volume
In certain noisy locations (background traffic, machinery or wind), the microphone volume may need
to be decreased. A symptom of this is one-way talk path, in which the distant party cannot be heard
over the speaker. A microphone volume pot is provided for increasing or decreasing the microphone
volume. Note: If the microphone volume is set too high or too low, one-way talk path may occur.
Microphone
(see section B)
ON
OFF
4
Rear View of the
E-60 Circuit Board
Mounting Plate
* Gel-Filled
Butt Connectors
(included)
E-60 is not
polarity sensitive
Red
(Ring)
Volume
DIP
Switches
ON
1
2
3
4
Viking C-200, C-250, C-500 or C-2000B
Entry Phone Controller (not included)
VIKING
MODEL C-2000B
©
VIKING
ELECTRONICS
HUDSON, WI 54016
ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER
1 2 3 4 5 6 7
8 9 10 11 12 13
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J7-
J8-
J9-
J10-
1
1
2
3
2
3
1
2
3
1
2
LED1
LED2
LED3
C
LED4
C
LED5
C
LED6
C
C
-or-
Programming
VIKING
*** Optional Viking
K-1900-5 Dialer or
K-1900-30 Multi-
Number Dialer
(not included)
**** C.O. Line
PABX/KSU Station
VIKING
©
Programmable
(programmed for
Tone Dialer
MODEL: K-1900-5
Quick Programming Guide
1. Call the phone connected to the dialer.
*
2. Answer phone. Enter
& security code.
(Factory set to 845464) Write your
security code below:
3. Enter your spped dial number & #00.
Note: For additional programming see
K-1900-5 Technical Practice.
Viking Electronics, Inc.
J11-
3
1
2
3
Hudson, WI 54016
C
LED7
C
LINE IN
PHONE
To dedicated phone, unused trunk/
line input of a phone system, or
Viking C-1000B Doorbox Controller
(as shown above) and fasten a wire
Speaker
Volume
(see section A)
Rear View of the
E-60 Circuit Board
Mounting Plate
Viking DLE-200B
or Analog
Two Way Ringdown
Circuit (not included)
ringdown)
VIKING
RINGDOWN
©
1
2
DLE-200B
RES
BUSY

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-60-ip seriesE-60-ssE-60 seriesE-60-whE-60-bk

Table of Contents