B. Wiring the E-35 Camera
1. Using RG59 for Video and CAT5 for Camera Power and Phone Board Audio (Recommended)
3-Wire Gel-Filled Butt
Back View of the E-35
Connectors included
(3M Scotchlok UR2)
ON
ON
1
1
2
2
ON
1
2
3
2. Using CAT5E or CAT6 for Video, Camera Power and Phone Board Audio (see Caution below)
Back View of the E-35
ON
ON
1
1
2
2
ON
1
2
3
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone
line. It is recommended that a surge protector be installed to protect against such surges.
* Note: Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable. Longer cable runs can be used if a passive or active video Balun transceiver is used on
each end of the cable. Generally, passive transceivers can achieve up to 750 ft cable runs where active transceivers can achieve up to 3000 ft runs depending on cable type, etc.
The type of video balun transceiver required is specific to your cable run length. For more information on video balun transceivers go to: www.northernvideo.com.
** Note: The maximum camera power supply wire run length is 1000 ft of 24 gauge wire (CAT 5/6), longer runs are possible by doubling pairs, increasing the wire gauge or using
up to a 22V DC 200mA power adapter.
*** Note: RG59 or RG6 with solid center conductor and 95% bare copper braid shield.
Caution: When routing CAT5E or CAT6 cable, maintain a minimum distance of 3 ft from any parallel high voltage wire (110 VAC) and a minimum of 2 ft from crossing any high voltage
wire. For installations where RF noise is expected (commercial applications) or wire runs are near high voltage (110 VAC) wires, a shielded video cable such as RG6 is recommended.
C. Adjusting the Camera
The camera can be tilted and rotated to your desired
position. A portable service (test) monitor can be used to
determine the correct viewing angle during installation.
Important: To prevent the edge of the faceplate from
being viewed in the video image, do not rotate the camera
beyond 30 degrees or tilt beyond 20 degrees.
Center conductor
stripped back 5/8"
Yellow (Video)
Twisted foil and braided shield
Yellow/Red
Black
**** Female "F" to Wire or "BNC" to Wire
Converter Cable (not included)
- Black (GND)
** Camera GND (-)
+ Red (12VDC)
** Camera Pwr (+)
Phone Board Audio In/Out (Tip)
Phone Board Audio In/Out (Ring)
3-Wire Gel-Filled Butt
Connectors included
(3M Scotchlok UR2)
Yellow (Video)
Video Out (+)
Video GND (-)
- Black (GND)
** Camera GND (-)
** Camera Pwr (+)
+ Red (12VDC)
Phone Board Audio In/Out (Tip)
Phone Board Audio In/Out (Ring)
*** RG59 or RG6 Shielded
Video Cable, up to 1000 ft
**** For ease of installation, a Viking Female
OR
"F" to Wire Converter Cable can be used (Part
# 261217) or "BNC" to wire converter cable
(Part # U213510) can be used. Go to
www.vikingelectronics.com
"Spare Parts" to order.
CAT5 Cable
W/O
Orange
** Up to 1000 ft
W/BL
Blue
CAT5E or
W/G
CAT6 Cable
(see Caution below)
Green
W/O
Orange
* Up to 150 ft
W/BL
Blue
+/- 30 degrees maximum
Vertical (Tilt)
Adjustment
+/- 20 degrees
maximum
4
"F"
"F" to Phono Plug
Connector
Adapter
(Radio
Shack part #278-252)
12V DC Adapter
and
click
on
Camera GND (-)
W/O
Orange
Camera Power (+)
(4) Crimp-on Splice
Connectors (not included)
Blue
W/BL
See page 3, section A
Wiring Phone Board
To unused input on TV, VHF
modulator, whole house video
distribution equipment, IP video
encoder (Axis M7001), etc.
Video Out (+)
Video GND (-)
W/G
Green
12V DC Adapter
Camera GND (-)
W/O
Orange
Camera Power (+)
(4) Crimp-on Splice
Connectors (not included)
Blue
W/BL
See page 3, section A
Wiring Phone Board
Horizontal (Rotation)
Adjustment
VIKING
©
To unused input on TV,
VHF modulator, whole
house video distribution
equipment, IP video
encoder (Axis M7001), etc.
!
(included)
120V AC
(-)
( + )
(-)
(+)
Phono (RCA) Plug,
F Connector, Etc.
!
(included)
120V AC
(-)
( + )
Call

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-35-ewp

Table of Contents