Layout drawing – brake module R8i

Module layout

7
9
1
DC connection busbars, + (a) and - (b)
2
Lifting eyes, front (a) and back (b)
3
Coolant in (a) and out (b) connectors
4
Handle
5
Fiber optic connectors
6
Quick connector (AC connection) (the counterpart fastened to the cabinet behind the module)
7
Terminal block X50 (auxiliary power input for internal boards)
8
Terminal block X51 and X52 (Safe torque off in inverter modules only)
9
Terminal block X53 (24 V DC power output)
10
Auxiliary voltage selector X59 (115 or 230 V)
11
Unpainted fastening hole. The grounding point between module frame and cabinet frame.

Coolant connectors

The coolant pipe inlet and outlet connectors are located at the bottom front of the
module. The connectors are for 16/13 millimeter PA (polyamide) pipe.
Operation principle and hardware description 21
2a
11
8
10
4
3a
3b
1a
1b
5
2b
6