Second Row: Log Data Information
This example shows the data text strings and data generated for the second row of log data.
Example of generated data:
01,0012,160107111230,0101,0201,0102,0201,0103,0206,0107,0005,0108,0209,0000,0000,0000,0000,0000,0
000,0000,0000,0000,0000,0000,0000,0000,0000,000002
No.
Item
1
Attribute
2
File number
3
Time stamp
*1
4
Monitor number 1
*2
5
Monitor number 1
6
Monitor number 2
7
Monitor number 2
:
:
22
Monitor number 10
23
Monitor number 10
24 to 27
Reserved
28
File number
*1
If there is no data log monitor selected, the text string of [0000] is generated.
*2
Refer to
Table 12.75
for information about unit codes.
Unit Code (Hex.)
Unit
00
01
Hz
02
RPM
03
%
04
VAC
05
VDC
06
A
07
sec
Third and Subsequent Rows: Log Data
This example shows the data text strings and data generated for the third row of log data.
Example of generated data:
02,0012,160107111239,1770,1770,00BE,0118,0028,0000,0000,0000,0000,0000,0000,0000,00000C
No.
Item
1
Attribute
2
File number
3
Time stamp
4
Log Monitor Data 1
5
Log Monitor Data 2
:
:
13
Log Monitor Data 10
YASKAWA SIEPC71061737B GA800 Drive Technical Reference
Number of
Characters
2
[01] shows that the record is a log data information record.
4
The [xxx] part of the [GLOG0xxx.csv] filename is a 3-digit decimal number in hexadecimal format.
12
Date file was generated
4
Monitor number selected by o5-03 [Log Monitor Data 1]
Ex.: 0101 (Dec.) for U1-01
4
Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
4
Monitor number selected by o5-04 [Log Monitor Data 2]
4
Unit code and number of decimal places used for the monitor selected with o5-04
:
:
4
Monitor number selected by o5-12 [Log Monitor Data 1]
4
Unit code and number of decimal places used for the monitor selected with o5-12
4
-
6
Row number (Hex.) in the data log file
Table 12.75 Unit Codes
Unit Code (Hex.)
Unit
08
PPR
09
kW
0A
Ω
0B
ms
0C
kHz
0D
PSI
0E
MPM
0F
FPM
Number of
Characters
2
[02] shows that the record is a monitor data record.
4
The [xxx] part of the [GLOG0xxx.csv] filename is a 3-digit decimal number in hexadecimal format.
12
Data log data was retrieved (YYMMDDHHMMSS)
4
Monitor number selected by o5-03 [Log Monitor Data 1]
4
Monitor number selected by o5-04 [Log Monitor Data 2]
:
:
4
Monitor number selected by o5-12 [Log Monitor Data 10]
12.11 o: Keypad-Related Settings
Description
Unit Code (Hex.)
Unit
10
H
11
V
12
us
13
min
14
°C
15
W
16
kWH
17
MWH
Description
Unit Code (Hex.)
Unit
18
0H
19
1A
1B
1C
1D
1E
1F